background image

© 2020, Elvaco AB. All rights reserved. The documentation and product are provided on an “as is” basis only and may contain deficiencies or in-
adequacies. Elvaco AB takes no responsibility for damages, liabilities or other losses by using this product. No part of the contents of this manual 
may be transmitted or reproduced in any form by any means without the written permission of Elvaco AB. Printed in Sweden. 

CMi4170 Quick Manual English

Version:  1.0  

CONTACT INFORMATION

Elvaco AB Technical support:

Phone: +46 300 434300 
E-mail: [email protected] 
Online: www.elvaco.com

User interface

Green LED & Red LED

Indication for start-up / reboot / 
switch-off

Push button

Start-up / reboot / switch off 
module

Configuration

Elvaco OTC app, Downlink or 
Engelmann optical configuration 
tool “Device Monitor”

Approvals

EMC

EN 301 489-1, EN 301 489-3

LoRa Alliance

LoRaWAN® Certified

SAFETY

The warranty does not cover damage to the product caused by usage in 
any other way than described in this manual. Elvaco AB can not be liable 
for personal injury or property damage caused by usage in any other way 
than described in this manual.

SERVER CONFIGURATION

Before CMi4170 is able to transmit messages on the LoRaWAN network, 
device information needs to be added to the network server. More 
specifically, the following parameters needs to be registered (in OTAA 
mode) in order to enable the network server to receive messages from 
the module:

• 

Device EUI (16-digit number printed on the device label)

• 

Application key

• 

Join EUI

NOTE 

If activation mode is set to “ABP” the following information will be 
needed: Network session key, Application session key and Device 
address. 

TECHNICAL SPECIFICATIONS

Mechanics

Dimensions

29 x 56 x 12 mm

Weight

9 g

Mounting

In module slot of Engelmann 
Sensostar S3/S3C

Electrical connections

Supply voltage

Internal meter battery or PSU 
(Engelmann External Power 
Supply)

Electrical characteristics

Nominal voltage 

3.0 VDC

Power consumption (max)

50 mA

Power consumption (sleep mode) ~2.5 µA

Environmental specifications

Operating temperature

+5 °C to +55 °C

Operating humidity

0 - 93 % RH, no condensation

Operating altitude (max)

2000 m

Usage environment

Indoors

Storage temperature

-20 °C to 60 °C

 

 

 

EU DECLARATION OF CONFORMITY 

 

This declaration of conformity is issued under the sole responsibility of the manufacturer: 

 

Elvaco AB, Kabelgatan 2T, S-434 37 Kungsbacka, Sweden.

 

 

 

 

 

Product

 

 

 

Year of CE-marking

 

 

 

CMi4170 

 

         

2020 

 

The object(s) of the declaration listed above is in conformity with the relevant Community 

harmonization legislation: 

Radio Equipment Directive (RED) 2014/53/EU 

Low Voltage Directive 2014/35/EU 

EMC Directive 2014/30/EU 

RoHS 2011/65/EU 

 

And are in conformity with the following harmonization standards or other normative documents: 

 

EN 62368-1 2018 (Safety requirements for information and communication technology equipment) 

EN 301 489-1 v2.2.3 (EMC standard for radio equipment and services) 

EN 301 489-3 v2.1.1 (EMC standard for radio equipment and services) 

EN 300220-1 v3.1.1 (SRD Low power radio equipment)  

EN 300220-2 v3.2.1 (SRD Low power radio equipment) 

EN 55032 CISPR 32 2015 (Radiated emission) 

 

EN 61000-4-2 2008 (Immunity to ESD) 

EN 61000-4-3 2006 (Immunity to RF field) 

EN 61000-4-4 2012 (Immunity to electrical fast transient/burst) 

EN 61000-4-5 2017 (Immunity to surge measurement) 

EN 61000-4-6 (Immunity to HF injections) 

EN 61000-4-11 (Immunity to voltage dips/short interruptions and variations) 

 

 

 

 

Kungsbacka, Sweden, 2020-01-13

 

 

Håkan Saxmo, Chief Technology Officer 

Radio characteristics

Frequency

868 MHz

Output power

14 dBm

Receiver sensitivity

-135 dBm

LoRaWAN characteristics

Device class

Class A, Bi-directional

LoRa version

1.0.2 Rev B

Activation

OTAA or ABP

Data rate

DR0-DR5 (250 bit/s-5470 bit/s)