background image

1

WS 2010

Radio Transmission

Weather Station

Operating Instructions

%

%

TEMP.

 TEMP.

TOTAL  

RAI NFAL L

RE LAT IVE AIR PRE SSURE

inHg 

N

S

W

TRE ND

HUMIDITY

HUMIDITY

NW

NE

SE

SW

E

Sensor

mph

°

F

°

F

AM

in

-20h -16h -12h -8h -4h -1h

Store

Sensor

Unit

Min / Max

Calibr.

Fast

Prog.

Indoor

Min / Max

Outdoor

Sensor

Reset

Wind      Rain

Al arm

WEAT HERS TAT ION    WS2000

0h

-24h

WS 2010

Содержание WS 2010

Страница 1: ...MP TEMP TOTAL RAINFALL RELAT IVE AIR PRESSURE inHg N S W TREND HUMIDITY HUMIDITY NW NE SE SW E Sensor mph F F AM in 20h 16h 12h 8h 4h 1h Store Sensor Unit Min Max Calibr Fast Prog Indoor Min Max Outdo...

Страница 2: ...2...

Страница 3: ...gram Mode 4 1 Setting the alarm min max values 4 2 Calibration 4 3 Changing units of measurement 4 4 Setting the clock 4 5 Changing the basic addresses of sensors with fixed assignments 5 Changing the...

Страница 4: ...e form of a wind rose displaying wind direction fluctuation instead of wind speed the wind direction can be displayed with 5 resolution Integrated clock for accurate assignment of measured values Stor...

Страница 5: ...n order to ensure the unique assignment of sensor data the basic unit should only be put into operation after the sensors have all be running for ten minu tes This is an important point because the se...

Страница 6: ...l or past 24 hrs or last hr 14 Air pressure tendency 15 Air pressure history over past 24 hours 16 Weather forecast symbol 17 Symbol to call in minimum values 18 Symbol to call in maximum values 19 Ti...

Страница 7: ...opped after approx 30 minutes and it switches to normal operation Test mode can be stopped at any time by pressing a button In order to assign the sensor data uniquely the test mode on the base statio...

Страница 8: ...sing Read the information on polarity in the battery compartment and insert the batteries accordingly Then close the compartment The sensor can then be brou ght to its installation site Note that thi...

Страница 9: ...without any other resources re quired Fill the recess with a litt le water and then align the lower part of the housing according to the spirit level principle After marking the installation position...

Страница 10: ...ystem without any interference At the factory each sensor of the type S 2010 A is defined as Sensor 1 and types S 2010 I and S 2010 IA as Sensor 2 The programmable assignment is illustrated in the adj...

Страница 11: ...wall and should be mounted as follows Mount the sensor wall bracket either exactly vertical on a wall using four screws or on a mast using the holding clamp Insert the sensor in the wall bracket and...

Страница 12: ...midity at the installation site of the indoor sensor Press the Indoor button once and the dew point appears refer to Glossary Press Indoor again to return to normal operation 3 2 Wind Pressing the Wi...

Страница 13: ...mum and maximum values of all the measured features since the last time the Min Max memory was deleted It is pos sible to select whether date or time of occurrence of the value should be displayed Min...

Страница 14: ...first alarm which arrives is displayed first with all the relevant sensor information In the case of an alarm the weather station remains in Alarm status until the Alarm button is pressed and the disp...

Страница 15: ...specific wind strength etc can now be adjusted in programming mode 4 1 Setting the alarm min max values Use the two arrow buttons and buttons and the Sensor button if neces sary to select the require...

Страница 16: ...to normal operation Rainfall transmitter compensation The rainfall measuring system leaves the factory in a very accurate state so that readjustment should not normally be necessary A compensation is...

Страница 17: ...the arrow button twice Only the time and date appear in the display The setting can then be made according to Table 1 Table 1 Set Time and Date Function Button Hour Minute Month Unit Day Sensor 4 5 Ch...

Страница 18: ...m interference in the transmission path needs to be taken into account This can generally be determi ned if data transmission from other sensors located nearby is not displayed either refer to Chapter...

Страница 19: ...ter or receiver empty Change batteries Check base station battery indicator Transmitter superimposed by source of interference radio headphones loudspeakers Eliminate the source of the interference or...

Страница 20: ...20 operating on the same channel every 3 minutes for approx 200 ms This interfe rence is negligable If possible change the channel on the unit experiencing inter ference...

Страница 21: ...er supply 4 x round cells Dimensions W x H x D 85 4 x 63 x 11 8 in 8 Ranges Under optimum conditions the open field range is 330 ft i e when there is visual contact between the transmitter and receive...

Страница 22: ...l display indicates changes of 2 hPa per part line Air pressure tendency Calculated from the developments over the past hours Dew point A temperature point which is dependent on the combination of a c...

Страница 23: ...buttons to set the required values Hold the button pressed in and the unit automatically counts up or down respectively Increase counter speed The counting speed factor can be increased by 10 by pres...