5
Operating instructions
Main Menu
Sub Menu Options/Values (Default Settings in BOLD)
Description
DMX Addr
001
-512
DMX Address Setting
DMX Mode
01CH (01 channel mode)
03CH
(03 channel mode)
DMX Channel Setting
Slave Mode
Slave Mode
DimMode
LED
HALOGEN
Dimming Curves Mode Setting
DimCurve
Linear
Square
I-Square
S-Curve
Dimming Curves Setting
Manual
CW:
STR:
000-
255
Manual Dimming Mode
NO DMX
Hold
Blackout
DMX Fail Setting
Temp.
–––°C
–––°F
Fixture Temperature
AutoLock
OFF
ON
Auto Lock Menu Setting
Op.Time
–––
Fixture Run Time
DFSE
OFF
ON
Default Factory Settings
Channel Value
Function
1
000-255 Master dimmer (0-100%)
1 channel mode (8 bit):
Channel Value
Function
1
000-255 Master dimmer (0-100%)
2
000-255 Dimmer fine
3
000-255 Strobe (slow-fast)
3 channel mode (16 bit):
IMPORTANT! PLEASE NOTE:
The LCD display for this fixture has a locking function which can be
enabled via the menu where after 20 seconds of inactivity it will lock. To unlock the menu press the
buttons in the following sequence
“UP”
,
“DOWN”
,
“UP”
,
“DOWN”
,
“ENTER”
.