Elumen8 CYC600 Скачать руководство пользователя страница 11

www.prolight.co.uk

CYC600 RGBW 150W COB Cyclorama Wash

 

 

User Manual

11

Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, 
105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in  
the chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output,  
see images below.

 
 
 
Also remember that DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote:

CABL10 – 2m

CABL11 – 5m

CABL12 – 10m

3-Pin:

CABL185 – 2m

CABL187 – 5m

CABL188 – 10m

5-Pin:

Содержание CYC600

Страница 1: ...Order codes ELUM122 CYC600 RGBW 150W COB Cyclorama Wash User Manual ...

Страница 2: ...s this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 60Hz Make sure that th...

Страница 3: ...display PowerCON input output 5 Pin XLR input output Eight leaf barn doors with integral gel frame Temperature controlled fan CYC600 RGBW 150W COB Cyclorama Wash Specifications CYC600 RGBW Power consumption 175W Fuse T2A 250V Power supply 100 240V 50 60Hz Dimensions 390 x 270 x 278mm Weight 5kg Order code ELUM122 0m 1m 2m 3m 4m 5m 90 x 113 Lux FULL ON R G B W 5028 1244 2068 480 2048 1257 311 517 1...

Страница 4: ...www prolight co uk CYC600 RGBW 150W COB Cyclorama Wash User Manual 4 Technical specifications 38mm 132mm 410mm 360mm 220mm 258mm 278mm 245mm 270mm 266mm 390mm 200mm ...

Страница 5: ...y 02 Function buttons 03 5 Pin DMX input 04 5 Pin DMX output 05 PowerCON input 06 PowerCON output 07 Fuse T2A 250V 08 On off switch 09 Safety eye 10 Earth point 11 Hanging bracket 12 Hanging bracket adjustment knobs In the box 1 x fixture 1 x barn door 1 x power cable 12 12 08 07 04 03 01 11 02 09 10 05 06 08 ...

Страница 6: ...s the material being used at the installation area and periodic safety inspections of the fixture and installation material If you do not have the relevant experience and or qualifications please do not attempt the installation yourself The installation should be checked annually by a qualified person The eLumen8 CYC600 RGBW 150W COB Cyclorama Wash can be operated in a number of mounting positions...

Страница 7: ...firm the setting To exit out of any of the above options press and hold the MENU button Main Menu Sub Menu Options Values Default Settings in BOLD Description DMX Address 001 512 DMX Address Setting Channel 4 CH DMX Channel Setting 9 CH Stand Alone Color Macro Speed 1 7 Colour Macros Color Dimming Red 000 255 Manual Mode Green 000 255 Blue 000 255 White 000 255 LEE 000 255 Col Temp 000 255 Strobe ...

Страница 8: ...49 055 Colour Macro 8 056 062 Colour Macro 9 063 069 Colour Macro 10 070 076 Colour Macro 11 077 083 Colour Macro 12 084 090 Colour Macro 13 091 097 Colour Macro 14 098 104 Colour Macro 15 105 111 Colour Macro 16 112 118 Colour Macro 17 119 125 Colour Macro 18 126 132 Colour Macro 19 133 139 Colour Macro 20 140 146 Colour Macro 21 147 153 Colour Macro 22 154 160 Colour Macro 23 161 167 Colour Macr...

Страница 9: ...00 015 No Function 016 255 Colour Temperature 2500K 7500K 7 000 007 No Function 008 015 Open 016 131 Strobe slow fast 132 139 Open 140 181 Strobe fast close slow open 182 189 Open 190 231 Strobe fast open slow close 232 239 Open 240 247 Random Strobe 248 255 Open 8 000 255 Master dimmer 0 100 9 000 255 Dimmer fine 0 100 DMX channel modes ...

Страница 10: ... 084 090 Colour Macro 13 0 30 255 20 091 097 Colour Macro 14 0 110 255 20 098 104 Colour Macro 15 0 100 255 80 105 111 Colour Macro 16 0 165 255 130 112 118 Colour Macro 17 0 115 255 10 119 125 Colour Macro 18 0 50 255 0 126 132 Colour Macro 19 0 128 128 0 133 139 Colour Macro 20 0 255 0 0 140 146 Colour Macro 21 0 255 0 0 147 153 Colour Macro 22 0 255 5 0 154 160 Colour Macro 23 0 255 0 25 161 16...

Страница 11: ...e allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a...

Страница 12: ...n line a cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal 3 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C DMX setup Termination reduces sig...

Страница 13: ...es that can be connected is 12 fixtures 240V or 6 fixtures 120V including the first fixture After the maximum number of fixtures are connected a new power run will need to be started Please note Caution should be used when power linking other fixtures to the CYC600 RGBW 150W COB Cyclorama Wash as the power consumption of other fixtures will vary Fixtures fitted with lamps often require 2 3 times m...

Страница 14: ...www prolight co uk CYC600 RGBW 150W COB Cyclorama Wash User Manual 14 ...

Страница 15: ...www prolight co uk CYC600 RGBW 150W COB Cyclorama Wash User Manual 15 ...

Страница 16: ...prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for envir...

Отзывы: