![ELTEX WB-15-W Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/eltex/wb-15-w/wb-15-w_user-manual_2397358029.webp)
WB-15-W. User manual
29
•
•
•
•
•
•
•
•
•
•
•
•
•
To enable access to the device via the web interface via HTTPS protocol, set the flag next to «WEB-HTTPS».
In the window that appears, it is possible to change the HTTPS port (by default, 443). The range of
acceptable values of ports, in addition to the default, from 1025 to 65535 inclusive;
To enable access to the device via Telnet, check the box next to «Telnet»;
To enable access to the device via SSH, check the box next to «SSH»;
To enable access to the device via NETCONF, check the box next to «NETCONF».*
*Access via NETCONF is not supported in the current firmware version 1.1.0.
WB-15-W software allows monitoring status of the device and configuring it via SNMP. In the «SNMP Settings»
submenu, you can configure settings of SNMP agent. The device supports SNMPv1, SNMPv2, SNMPv3.
To change the SNMP settings, check the box next to «SNMP», apply the configuration and then go to the SNMP
submenu.
roCommunity
–
a password to read the parameters (by default:
public
);
rwCommunity
–
a password to configure (write) parameters (by default:
private
);
TrapSink
–
IP address or domain name of SNMPv1-trap message recipient in HOST \[COMMUNITY \[PORT\]
\] format;
Trap2Sink
– IP address or domain name of SNMPv2-trap message recipient in HOST \[COMMUNITY \
[PORT\]\] format;
InformSink
– IP address or domain name of Inform message recipient in HOST \[COMMUNITY \[PORT\]\]
format;
System Name
–
device name;
Sys Contact
–
device vendor contact information;
Sys Location
–
device location information;
Trap community
–
password enclosed in traps (default value: trap).
Note that the ports for the HTTP and HTTPS protocols should not have the same value.