_____________________________________________________________________________
____________________________________________________________________________
50
LTP-8X optical line terminal
Event
Description
Threshold
link
Ethernet port state changed (up/down)
-
logout
User logged out
-
ont_dying_gasp
Dying Gasp signal received from ONT
-
redundancy channel
switch
Switch to redundant channel
-
redundancy master
channel fail
Emergency switch to redundant channel
-
ont_rei
Remote Error Indication (REI)
-
ont_power_off
ONT power off
-
config_change
OLT configuration changed
-
shutdown
SNMP agent shut down
-
oms
OMS-MIB operation completed successfully / with errors
-
ont_state_changed
ONT state changed
-
ont_config_changed
ONT configuration changed
-
channel_state_change
d
OLT channel configuration changed
-
pon_alarm_channel
An event related to OLT channel
-
pon_alarm_onui
An event related to ONT
-
ont_update_inprogress ONT firmware is updating
-
olt_device_reset
OLT chip reset
-
ont_signal_degrade
Signal attenuation in line is too high for ONT
-28 dBm
ont_high_received_opt
ical_power
Signal attenuation in line is too low for ONT
-8 dBm
olt_device_not_workin
g
GPON OLT configuration was loaded successfully / with errors
-
* The value can be adjusted.
Every record in the active alarms log has the parameters specified in Table 13.5 which are specified for every
event type.
Table 13.5. Parameters of Events in Active Alarms Log
severity
Describes the event severity. Has four states (info, minor, major, critical)
send-on-in
Specifies whether an SNMP trap should be sent when an event is added to the log. Has
two states (true/false)
send-on-out
Specifies whether an SNMP trap should be sent when an event is deleted from the log.
Has two states (true/false)
ttl
The time in seconds an event exists in the active alarms log (from 1 to 2,147,483,647). Is
specified in seconds. The parameter has several special values. 0—the event exists in the
log until a normalising event received. -1—SNMP trap is sent (if specified), but the event
is not recorded to the alarms log.
13.5.1
Active Alarms Log Configuration
Step 1.
To configure the active alarms log, switch to the
configure view
.
LTP-8X# configure