3.6 Disconnecting the high voltage cable
Warning!
Electric shock hazard!
Work may be carried out only if:
• the supply voltage to the generator has been disconnected,
• the machine is at a standstill because the bars pick up charges if the
material web is running.
Take off the clip at the generator and/or the R131 bar, using a 3 mm screw
driver. Then pull out the cable.
A conversion kit comprising terminal adapter, tubular rivet, split-pin plug
and washer is available as accessory from Eltex.
3.7 Connecting the supply voltage
Supply voltage connection to the high voltage generator is made directly
via the mains plug using the enclosed mains cable.
Warning!
Disconnect and/or connect the mains cable on the socket only when off-
load.
When using external protection fusing for generators, the following circuit-
breaker must be used:
6 A; tripping characteristic D in compliance with DIN VDE 0641, part 11;
EN 60898-1.