Operating Instructions

R130A / R131A Charging Bar
EXR130A Charging Bar

BA-en-3020-2101

F01

0

39

y

Содержание EXR130A

Страница 1: ...Operating Instructions R130A R131A Charging Bar EXR130A Charging Bar BA en 3020 2101 F01039y...

Страница 2: ...2 BA en 3020 2101_R130A R130A3L R131A EXR130A EXR130A3L...

Страница 3: ...ling 12 3 4 Installation of the charging bar 12 3 5 Connecting the high voltage cable to the generators KNH18 KNH34 KNH35 KNH64 KNH65 to the distributor box KNHV3 KNHV6 and to the charging bar R131A 1...

Страница 4: ...4 BA en 3020 2101_R130A R130A3L R131A EXR130A EXR130A3L...

Страница 5: ...interference if the materials used such as films foils papers etc adhere to each other The charging bar EXR130A EXR130A3L is available for use in the Ex zone The bars are operated with the appropriat...

Страница 6: ...pplications The parallel configuration of two or more bars allows surface covering charging or operating the unit at high web speeds The maximum total length of the charging bar is 3985 mm 1 1 R130A R...

Страница 7: ...cable can be axial or at a right angle to the bar R131A bar The connection of the high voltage cable is detachable and only available axial to the bar 1 2 R130A3L EXR130A3L charging bars R130A3L EXR1...

Страница 8: ...ration of the charging bars is only guaranteed by using these Eltex generators Caution When using the EXR130A EXR130A3L charging bar please note the operating instructions for the appropriate system a...

Страница 9: ...spark dis charge and may lead to a risk of injury Disconnected high voltage plugs are not permitted or have to be grounded see chapter 5 Mainte nance page 21 Install the bar such that no creepage curr...

Страница 10: ...e units are clean at all times Dirt results in malfunctions and in premature wear of the units Do not touch the emission tips risk of injury If the high voltage supply is connected reflex responses to...

Страница 11: ...site of installation and or use of the units is outside the control of Eltex contact protection against inadvertent contact of the bars and of live components by personnel as specified by the employer...

Страница 12: ...ble 3 2 Length of the high voltage cable The standard length of the high voltage cable feeding the charging bar is 5 meters Special lengths on request For cable extension use high voltage distributor...

Страница 13: ...The GRP holder is bolted with sliding nuts in the fluting of the charging bar Any of the three flutings may be used for installation Possible applications Stabilizing material webs reducing the air g...

Страница 14: ...ctive foil laminating decorative mate rial etc Fig 5 Installation example using Eltex fitting material 1 Bar 2 Eltex fitting material 3 Machine wall Z00067y a 200 1 2 3 Fig 6 Installation example usin...

Страница 15: ...age cable to be mounted with a minimum clearance in air of 200 mm before attaching it to the machine wall Depending on intended use the spacing distance a between the charging bar and the material web...

Страница 16: ...ection Max bolt depth 6 5 mm Torque 4 Nm metallic screw and sliding nut 0 4 Nm plastic screw and sliding nut Secure bolts against working loose e g Loctite 243 C Sliding nut Total length below 1 meter...

Страница 17: ...s at a standstill because the bars pick up charges if the material web is running Method Connect the bars via the prefabricated high voltage cable Push the high voltage cables up to the stop into the...

Страница 18: ...the bars via the prefabricated high voltage cable Push the high voltage cables up to the stop into the socket connection Finally the crew connection is tightened 9 9 1 High voltage outputs 10 High vol...

Страница 19: ...ltage to the generator has been disconnected the machine is at a standstill because the bars pick up charges if the material web is running Take off the clip at the KNH_ _ generators the KNHV_ distrib...

Страница 20: ...lications in which the material to be charged has a high intrinsic resistance and where no creepage currents caused by contamination is expected The current must not be allowed to exceed 1 mA per mete...

Страница 21: ...5 Pa commercial compressed air pistol and a brush with soft plastic bristles Clean grease ink glue paper dust etc off the discharging bar using a suitable solvent e g cleaning gasoline Do not soak the...

Страница 22: ...applies only if the operating and assembly instructions spe cified by Eltex have been observed The warranty period begins on the date of delivery In the event of defects occurring during the warranty...

Страница 23: ...l and water and a brush with soft plasctic bristles Use a suitable sol vent to remove dirt or grease see Chapter 5 Maintenance No continuous sparking electric arc must be visible on the bar tips Cauti...

Страница 24: ...d synthetic GRP PU special alloy 0 60 C 32 140 F max 60 relative humidity non dewing max 30 kV DC R130A3 R130A3L R131A3 max 60 kV DC R130A6 for voltages higher 60 kV there are special bar designs avai...

Страница 25: ...age generators series HSG61 and POWER CHARGER PC_ _ prefabricated high voltage cable in plastic tube with plug for the high voltage generator length 1 99 m standard length 5 m see Fig 13 max 3 985 mm...

Страница 26: ...mm AL Active length GL Total length EL Installation length n Whole number depending on active length Z for operating voltage below 30 kV Z1 Z2 35 mm for operating voltage below 60 kV R130A6 Z1 Z2 60 m...

Страница 27: ...th flexible tube for 30 kV charging bars for connection to the generators KNH_ _ Plug Q Kit for cutting the high voltage cable to size with flexible tube for 30 kV charging bars bar side for R131A onl...

Страница 28: ...ible tube for 60 kV charging bars for connection of the generator POWER CHARGER PC_ _ external diameter of the cable min 6 55 mm resp modification set for charging plug X high voltage cable Bedea KWV...

Страница 29: ...rges being picked by the bars Ignoring this safety notice may result in damage to machinery and personal injury Preparing the connection The quick plug in connection consists of two sections the actua...

Страница 30: ......

Страница 31: ......