Device schematics: 
 
1.

 Thermic switch 

 

2.

 

Reset

 (of thermic switch) 

3.

 Heat block 

4.

 Temperature sensor 

5.

 Flowmeter 

6. 

Triac 

7.

 Connecting block 

8. 

Thermic safety fuse 

9.

 Hot water outlet 

10.

 Cold water inlet 

 

 

Electric schematics: 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
Device installation - remarks: 
 

The installation must only be carried out by qualified installer and installed in accordance to all national 

and local electrical and plumbing regulations.  

 

 

1.

 Make sure the device is not mechanically damaged and complete. 

2.

 Do not install in premises where temperature falls below 0°C. 

3.

  Compare  your  installation  with  device  requirement  (power  allocation,  supply  voltage,  water  pressure, 

earth, wires cross section, proper fuses both over-current and differential-current, etc.). 

4.

 Device needs to be earthed! 

5.

 Main power circuit needs to be protected both over-current and differential-current fuses. 

6.

 Do not install close to strong magnetic field. 

7.

 In case of longer idle time of device, power supply needs to be disconnected. 

8. 

We  highly  recommend  fitting  an  isolation  valve  and  ball  valve  before  the  unit  to  close  system  before 

removal of the tap and servicing.

  

 

Содержание Grzejemy jak Kawaleria Admiral Series

Страница 1: ...ul Przemysłowa 5 86 200 Chełmno www elterm pl Operating and assembly manual Electric instantaneous flow heater Admiral build in AsC and AsC W electric heating boilers or sold separately Available power 7 5kW 12kW 15kW 18kW 21kW ...

Страница 2: ...ulation material it is natural if there might be a bit of smell or green blue smoke when the unit is used for the first time 10 In case of cable wire damage you must contact qualified electrician to replace it with a new wire s 11 Please flush the system through completely by opening the hot tap on the water heater circuit furthest away from the heater Allow all air and debris to pass before closi...

Страница 3: ...shower Water is not pre heated and stored but heated directly when needed As a consequence no energy is lost in the process Admiral has state of the art patented heat exchanger solution which eliminates scale deposition most common issue with standard flow devices with build in heaters Water is completely separated from live components what ensures high durability and 100 safety Use Electric insta...

Страница 4: ... the device is not mechanically damaged and complete 2 Do not install in premises where temperature falls below 0 C 3 Compare your installation with device requirement power allocation supply voltage water pressure earth wires cross section proper fuses both over current and differential current etc 4 Device needs to be earthed 5 Main power circuit needs to be protected both over current and diffe...

Страница 5: ...refully before removing the front cover Once your product has been fixed in accordance with the diagrams above please connect your product to the mains water supply using a 1 2 tap pipes to the blue connection of the unit Electrical works 1 The installation must only be carried out by qualified electrician in accordance with all regulations 2 The unit must be properly earthed and proper fuses need...

Страница 6: ...1 shown on display Device will return to standard mode after temperature cools down to 58 C Automatics also monitors current loss which when detected is indicated by E2 shown on display E3 is shown when temperature sensor has been damaged Admiral also protects build in heating element from overheating electric supply is turned off when heating element temperature reaches 95 C 7 5 kW and 90 C 12 21...

Страница 7: ...ed by any regular maintenance procedures please ensure consistent water flow it is recommended for the following maintenance 1 Periodically remove scale and dirt that may build up at the aerator of the faucet or in the shower head Please periodically clean inlet strainer and the shower to keep a free water flow 2 There is a built in meshed gasket screen at inlet connection which should be cleaned ...

Страница 8: ...Too high water temperature setting B Too low water pressure A Decrease water temperature setting B Increase water flow Water is too cold A Too low water temperature setting B Too high water demand compared with device power A Increase water temperature setting B Decrease water flow e g use only 1 intake point at one time Water pressure is dropping Mesh filter is filled Check and clean filter No wa...

Отзывы: