background image

HIT

 Inst Issue 14: 18.10.17

1.

 WARNING 

This fan is fitted with a non self-resetting thermal cut-out which switches    

 

the fan off in the event of a fault condition. To reset, turn the power off for one   

 

 

minute, then back on. Only a suitably qualified and competent person may carry out    

 

maintenance after the electrical supply has been isolated.

 CAUTION 

In order to avoid a hazard due to inadvertent resetting of the thermal cut-   

 

out, this appliance must not be supplied through an external switching device, such as  

 

a timer, or connected to a circuit that is regularly switched on and off by the utility. 

 WARNING 

The appliance can only be used indoors. 

2. General

2.1 

It is important these Installation and Maintenance Instructions are fully adhered to.

2.2 

Full details of the unit supplied are shown on the product nameplate. If in doubt about any  

 

detail contact Hydor or its agents   for clarification.

2.3 

All electrical installation must be carried out by suitably qualified and competent    

 

 

personnel in accordance with all current statutory requirements.

2.4 

These instructions cover only the Hydor product and do not include  the supply or  

 

 

installation of any safety equipment that may be required e.g. adequate guarding or  

 

 

protection from rotating parts and proper electrical isolation.

2.5

 

Any declarations made by Hydor about product installation and safety, are dependent on  

 

the fan equipment being used within installations which themselves meet the  

 

 

 

requirements of the  relevant Standards and Directives of your region.

2.6 

The fan is designed for use in up to 95% relative humidity. The fan is not suitable for  

 

 

corrosive or explosive atmospheres.

2.7    The installer should provide easy access to the fan to facilitate future maintenance.
2.8    The installer should ensure the fan is adequately supported.
2.9a 

The below statement is only applicable to the European market. 

 

  This appliance can be used by children aged from 8 years and above and persons with  

 

 

  reduced physical, sensory or mental capabilities or lack of experience and knowledge  

 

  if they have been given supervision or instruction concerning use of the appliance in a safe  

 

  way and understand the hazards involved. Children shall not play with the appliance.  

 

  Cleaning and user maintenance shall not be made by children without supervision.

2.9b 

The below statement is only applicable to the non-European market. 

 

  This appliance is not intended for use by persons (including children) with reduced    

 

 

  physical, sensory or mental capabilities, or lack of experience and knowledge, unless they   

 

  have been given supervision or instruction concerning use of the appliance by a person    

 

  responsible for their safety. Children should be supervised to ensure that they do not play    

 

  with the appliance.

HIT 

Centrifugal In-Line Fan

Содержание Hydor HIT Series

Страница 1: ... 5 Any declarations made by Hydor about product installation and safety are dependent on the fan equipment being used within installations which themselves meet the requirements of the relevant Standards and Directives of your region 2 6 The fan is designed for use in up to 95 relative humidity The fan is not suitable for corrosive or explosive atmospheres 2 7 The installer should provide easy acc...

Страница 2: ...e with these instructions and current statutory requirements The installation and initial adjustments should be carried out by a qualified and competent technician Hydor Limited should be consulted before substituting or fitting parts from another manufacturer It is the responsibility of the installer to verify that the installation is in accordance with the following standards and the owner is gi...

Страница 3: ...nd HIT315 Screw bracket side to fan using self tapping screws a Bolt the bracket support spacer using the button head screws Mounting bracket set supplied HIT200 HIT250 and HIT315 2 off bracket sides 1 off bracket support spacer Fixings set supplied a 4 off M4x8mm Phillips hexagon with pad flange head self tapping screws b 4 off M4x15mm button head screws c 4 off M4 hexagon nuts d 4 off flat washe...

Страница 4: ... separated and fixed into the terminal strip connections Strip each individual core back 10mm exposing the cable Ensure the dome cap is tightened enough that the cable is securely clamped and cannot move Tool requirments not supplied 24mm Spanner Terminal screw driver 4 7 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order...

Страница 5: ...es Article No Code Supply FL Amps Watts r min 007580 HIT100 220 240V 1Ph 50 60Hz 0 14 0 13 26 25 2725 3150 007578 HIT125 220 240V 1Ph 50 60Hz 0 14 0 12 26 25 2690 3200 HIT150 HIT150 220 240V 1Ph 50 60Hz 0 28 0 36 65 84 2595 2858 007414 HIT160 220 240V 1Ph 50 60Hz 0 24 0 30 55 70 2700 3100 007133 HIT200 220 240V 1Ph 50 60Hz 0 46 0 60 105 130 2565 2900 007667 HIT250 220 240V 1Ph 50 60Hz 0 48 0 57 10...

Страница 6: ...00 315 O5 E C A DIA B D DIA F G 45 25 25 Product Code A B C D E F G Weight kg HIT100 98 204 130 237 284 270 47 3 7 HIT125 123 202 130 237 284 270 47 3 7 HIT150 148 195 165 278 326 312 47 3 6 HIT160 158 195 165 278 326 312 47 3 6 HIT200 198 242 190 333 392 372 100 5 5 HIT250 248 210 190 333 392 372 100 5 3 HIT315 313 280 227 400 460 440 100 8 8 150 150 150 ...

Страница 7: ...hed spur unit 240V 1Ph 50 Hz SUPPLY 220V 1Ph 60 Hz SUPPLY GREEN YELLOW BROWN RED BLUE YELLOW WHITE E L3 LOW L2 MED L1 HIGH WHITE WHITE CAP BLACK FAN WHITE WHITE CAP YELLOW WHITE BLACK BLUE RED BROWN L L3 L2 L1 N E L E N Switched spur unit 220 240 1Ph 50 60Hz SUPPLY 220 240 1Ph 50 60Hz SUPPLY 8 Wiring 8 1 HIT 100 125 8 2 HIT 150 315 ...

Страница 8: ...Alexandria NSW 2015 Tel 61 02 8073 3310 Fax 61 02 8073 3320 Email info idealairgroup com au Web idealairgroup com au AMS 11 Ingrid Road Montague Gardens 7442 Cape Town Western Cape Tel 27 0 21 552 1077 Fax 27 0 21 552 2797 Web fans co za Elta Fans Building Services 46 Third Avenue Pensnett Trading Estate Kingswinford West Midlands DY6 7US UK Tel 44 0 1384 275800 Fax 44 0 1384 275810 Email bs eltaf...