background image

10. Close the terminal block flap and secure with the screw. 

11. By pressing the upper and lower clips, fit the front cover back onto the fan body. 

12. Switch the mains power supply on and check that the fan is working correctly. 

 

Panel Installation—Recess Mounting (Fig. 2B) 

 

1. 

Using  the  template  supplied,  mark  out  and  cut  a  hole  in  the  panel. 

Read  the           

instructions on the template sheet carefully.  

2. 

Fig.  1B  -  By  pushing  the  clip  using  a  small  screwdriver  pull  the  front  cover  (1) 

away from the fan body (2). 

3. 

The  fan  body  (2)  is  secured  to  the base  frame  (4)  by  4 screws.  Take  out each 

screw from the four corners (6) to dismantle and release the base frame.  

4. 

Take out the screw that secures the terminal block flap (5) to the fan body (2). 

5. 

Fig. 4. - For side exit installations, the spigot assembly (9) can be repositioned. To 

do this, remove the spigot assembly (9) from the fan body (2). Rip off the guide 

vane  (8)  from  the  fan  body  and  reattach  the  spigot  in  a  side  orientation  in  the    

desired direction.  

6. 

Attach the ducting to the spigot (9). 

7. 

Feed the cable through the hole in the terminal block (Fig. 3) 

8. 

Using appropriate fixtures, screw the fan body (2) into the hole in the panel. 

9. 

Follow instructions for 

Electrical Connections and Wiring in B.

 

10.      Close the terminal block flap and secure with the screw. 

11.      By pressing the upper and lower clips, fit the front cover back onto the fan body. 

12. 

Switch the mains power supply on and check that the fan is working correctly. 

 

Wall Installation—Surface Mounting 

Using 100mm Elta Fans Wall Kit. 

 

1. 

Drill a Ø115mm hole through the wall, ensuring sufficient space for the fan to be 

installed. 

2. 

Insert  the  wall  sleeve  with  the  wider  diameter  sleeve  facing  the  room  side  and 

cement both ends in place, flush with the wall. The wall sleeve must be angled 

downwards to drain any condensation to outside. 

3. 

To fix the outside grille, use the back plate as a template and mark the fixing holes  

on the wall. Drill and plug the wall to fix the back plate securely into position.  

4. 

Secure  the  outside  grille  onto  the  back  plate  with  the  screws  provided,  making 

sure that the louvers are directed downwards. 

5. 

Fig.  1B  -  By  pushing  the  clip  using  a  small  screwdriver  pull  the  front  cover  (1) 

away from the fan body (2). 

6. 

The  fan  body  (2)  is  secured  to  the base  frame  (4)  by  4 screws.  Take  out each 

screw from the four corners (6) to dismantle and release the base frame.  

7. 

Screw the base frame (4) to the wall using appropriate fixtures ensuring that the 

opening for the spigot lines up correctly with the hole made when the fan body is 

re-attached. 

8. 

Take out the screw that secures the terminal block flap (5) to the fan body (2). 

9. 

Feed the cable through the hole in the terminal block (Fig. 3). 

10. 

Reassemble the fan body (2) to the base frame (4) and secure with 4 screws 

11. 

Follow instructions for 

Electrical Connections and Wiring in B.

 

12.      Close the terminal block flap and secure with the screw. 

13.      By pressing the upper and lower clips, fit the front cover back onto the fan body. 

14.      Switch the mains power supply on and check that the fan is working correctly 

 

Содержание CETO 250

Страница 1: ...CETO 250 Instruction leaflet Instruction lea et CETO 250...

Страница 2: ...NNING THE INSTALLATION PROCESS SAFETY AND RECOMMENDATIONS All wiring must comply with Building Regulations and the current I E E Wiring Regulations BS7671 or the equivalent standards for your country...

Страница 3: ...INSTALLATION 72 1 2 3 4 6 7 6 7 5 8 Fig 1 Fig 2A Fig 2B 9 3 Fig 1B...

Страница 4: ...Fig 3 Fig 5A Fig 6A N LA LB Fig 4 L N N A L B L L N N LA LB Fig 5B L C N LA N LB L N REB N A L LB Fig 6B CETO 250 M...

Страница 5: ...Fig 9A Fig 7A L N N L LS L N N L LS N L LS N L LS 15 30 A 2 T min 80 90 70 60 T min HR 20 30 1 10 L N N L LS Fig 7A Fig 7B L N N L LS Fig 8A Fig 8B Fig 9B CETO 250 T CETO 250 HT...

Страница 6: ...ot fix elbow bends directly to the spigot assembly Elbow bends should have a radius as large as possible Panel Installation Surface Mounting Fig 2A 1 Cut a 105mm hole through the panel ensuring suffic...

Страница 7: ...n is working correctly Wall Installation Surface Mounting Using 100mm Elta Fans Wall Kit 1 Drill a 115mm hole through the wall ensuring sufficient space for the fan to be installed 2 Insert the wall s...

Страница 8: ...operation with a switch Fig 6B Fan operating with an REB variable speed controller CETO 250 T Models with adjustable timer The timer enables the fan to operate for the time set after the switch has be...

Страница 9: ...e selected value It stops when the humidity level drops below this value and when the time set by the timer has elapsed When the fan operates at slow speed in timer mode 2 Automatic operation working...

Страница 10: ...GUARANTEE The CETO 250 range products are covered by a three year guarantee subject to the specified maintenance stated within this booklet...

Страница 11: ......

Страница 12: ...Elta Fans 46 Third Avenue Pensnett Trading Estate Kingswinford West Midlands DY6 7US United Kingdom Tel 44 0 1384 275803 Fax 44 0 1384 275810 E mail residential eltafans co uk Ref 9023041400...

Отзывы: