INSTALLATION 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2.1

 

CABLING AND CONNECTING

 

 
2.1.1.  

Connect  antenna  to  GSM  module.  Antenna  shall  be  positioned  as  far  from  the  GsmAlarm-
300  module  as  possible.  No  winded  antenna  cable  is  recommended  to  be  left  near  the 
GsmAlarm-300. 

 
2.1.2.

 

Insert a SIM card with PIN code OFF.  

 
2.1.3.

 

Connect  the 

CENT

  contacts  to  the  security  centrale  telephone  line  input.  During  testing, 

parallel ordinary phone device with tone dial may be connected. 

 
2.1.4.

 

Connect the co12V and GND to the protection system power source. 

 
2.1.5.

 

Contacts LINE are used to connect the wire telephone line. The telephone line is advised to 
connect later - in the end of adjustment. 

 
2.1.6.

 

The  contact 

C2

  (PSTN  Fail)  -    MOSFET  "open  drain"  output    -  is  used  to  warn  about  the 

telephone  line  (PSTN)  failure.  This  output  is  activated  (connected  with  the  ground  wire 
GND) in the case of telephone line failure after 15 seconds. 

 
2.1.7.

 

The  contact 

C3

  (GSM  Fail)  –  MOSFET  "open  drain"  output  -  is  used  to  warn  about  GSM 

communication failure. This output is activated (connected with the ground wire GND) in the 
case of GSM communication failure after 15 seconds. 

 
2.1.8.

 

Reserve contacts 

Z1

 and 

Z2

 inside the GsmAlarm-300 module are free and may be used to 

connect additional wires (e.g. tamper circuitry). 

LINE

CENT

GSM Antenna

Tel.

Line

Ground

SIM

Card

GsmAlarm-300

Dual Band Module

+12V GND

POWER

Supply

10.5 ... 15V

+

-

Z2

Z1

Reserved

Contacts

GSM 900/1800

Dialler

MO D EM

MO D E

R EAD Y

LINE

Reader

Visual indicators (LEDs)

Connector

To

In

C2

C3

GSM
Fail

PSTN
Fail

 

Содержание GsmAlarm-300

Страница 1: ...call the GsmAlarm 300 number and control the system from their phones using DTMF instructions as follows connect to the GSM service provider s operator and learn balance of the SIM card account ask for SMS carrying programmed numbers of the users SMS center and GSM operator s information ask for SMS carrying information about GsmAlarm 300 communication quality and power source voltage Caling user ...

Страница 2: ... telephone line is advised to connect later in the end of adjustment 2 1 6 The contact C2 PSTN Fail MOSFET open drain output is used to warn about the telephone line PSTN failure This output is activated connected with the ground wire GND in the case of telephone line failure after 15 seconds 2 1 7 The contact C3 GSM Fail MOSFET open drain output is used to warn about GSM communication failure Thi...

Страница 3: ...tate indicator Out system is not operating Blinking system is operating but no SMS center nor a single user number have been programmed Continuously On system is ready for work 2 2 4 LINE red wire telephone line indicator Out no wire line LINE communicating through GSM network Continuously On wire line LINE is present communicating through wire line 3 PROGRAMMING GsmAlarm 300 may be used without a...

Страница 4: ... receive information of the GsmAlarm 300 SIM card account balance If programmed correctly user gets a SMS with newly programmed numbers 3 2 CHANGING SMS PASSWORD In order to change manufacturer programmed SMS password send GsmAlarm 300 the following SMS AAAAAAAA PASSW ABCDefgh AAAAAAAA old password PASSW password change instruction ABCDefgh new SMS password It must have 8 digits If programming ins...

Страница 5: ...rogrammed 5 CONTROL WITH DTMF INSTRUCTIONS By calling GsmAlarm 300 user may control the system with DTMF instructions GsmAlarm 300 answers after 3 4 calling tones user hears three confirming tones DTMF instruction Purpose Connection with GSM operator account balance checking Note this command is operating only if the brief number SRVNR has been programmed and if GSM operator conference communicati...

Страница 6: ...ous 6 V Outputs C2 GSM Fail and C3 PSTN Fail Type Active state Inactive state Maximum commutated current Maximum commutated voltage Resistance in active level MOSFET open drain Connected with GND Open contact 200mA 20 V 40 Ω GSM module Operation frequency Maximum RF output power 900 1800 MHz 2W 1W Wire line GSM commutator relay Power source voltage 10 5 15V DC Current consumption Non activated sta...

Отзывы: