Checking the usage

Electronic index EI 

 for diaphragm 

gas meters BK..B

The electronic index EI3 indicates the volume at base 

conditions. It can be used for reading out absolute 
consumption values and for retrieving consumption 
data for the various tariffs.

This function is only guaranteed when used within the 

specified limits – see page 6 (Technical data). Any 
other use is considered as non-compliant.

Type code

Code

Description

BK-G

Diaphragm gas meter

 

0 
6 

5 

40

Flow rate 

0.06 – 10  m

3

/h 

0.1 – 16  m

3

/h 

0.16 – 25  m

3

/h 

0.25 – 40  m

3

/h 

0.40 – 65  m

3

/h

B

Volume at base conditions

Part designations

BK-Gx

DE-07-MI0

02-PTB0

01

12345

678

Q max 

Q min 

M07  01

02

5

2

1

4

3
6

8

7

  Gas meter with electronic index 

 Display

  User keys

4

  Opto-adapter interface

5

  Service cover

6

  Pulse output

7

   Pressure test point with sealing sleeve (optional)

8

  Thermowell (optional)

Type label/Index plate

BK-..B

class 1,5

Q

 

max

 

m

 

g

b

b

Q

 

min

 

p

 

max

 

M12  0102

Vb

12345678

2012

002545632734

ATEX

 

The electronic index is suitable for use in po-

tentially explosive atmospheres. For the exact 
use (zone), see ATEX sticker on the diaphragm 
gas meter or see “Operating instructions for 
diaphragm gas meters BK-G1.6 to BK-G25” 

→ 

http://docuthek.kromschroeder.com/doclib/
main.php?language=1&folderid=400041&by_
class=2&by_lang=-1

   “Instruction Manual, Industrial Diaphragm Gas 

Meters Type BK-G40 · BK-G65 · BK-G100 
and  Type BK-G40T · BK-G65T · BK-G100T” 

→ 

http://docuthek.kromschroeder.com/doclib/
main.php?language=1&folderid=400045&by_
class=2&by_lang=-1

Installation

Installing the gas meter

 

For installing the gas meter in the pipe-
work, see “Operating instructions for dia-
phragm gas meters BK-G1.6 to BK-G25” 

→ 

http://docuthek.kromschroeder.com/doclib/
main.php?language=1&folderid=400041&by_
class=2&by_lang=-1

   “Instruction Manual, Industrial Diaphragm Gas 

Meters Type BK-G40 · BK-G65 · BK-G100 
and  Type BK-G40T · BK-G65T · BK-G100T” 

→ 

http://docuthek.kromschroeder.com/doclib/
main.php?language=1&folderid=400045&by_
class=2&by_lang=-1

Operating the electronic index

 

The display on the index is switched off.

 

 

 Briefly press any key.

 

A beep sounds and the main screen appears.

Main screen

*

0000004

.00

m

3

*Current  meter  reading

  

Tariff: F01

1

2

3

  Menu area

  Information area

  Status line (symbols)

Содержание themis plus

Страница 1: ...ns may only be carried out by qualified gas technicians Electrical interventions may only be carried out by qualified electricians Conversion spare parts All technical changes are prohibited Only use OEM spare parts Transport On receipt of the product check that the delivery is complete see page 2 Part designations Report any transport damage immediately Storage Store the product in a dry place Am...

Страница 2: ...for use in po tentially explosive atmospheres For the exact use zone see ATEX sticker on the diaphragm gas meter or see Operating instructions for diaphragm gas meters BK G1 6 to BK G25 http docuthek kromschroeder com doclib main php language 1 folderid 400041 by_ class 2 by_lang 1 Instruction Manual Industrial Diaphragm Gas Meters Type BK G40 BK G65 BK G100 and Type BK G40T BK G65T BK G100T http ...

Страница 3: ...ally The Current meter reading main screen appears when switching on the index If you are in a different menu the display will automatically change back to the main screen when no user key has been pressed for 30 s and switches off after a further 30 s You can navigate from the main screen to the various menus such as Date and time UTC using the user keys Menu overview Current meter reading Genera...

Страница 4: ...ss further information Here the active tariff program is displayed as are the date and time of activation Tariff information ID Green Spring Demo From 01 01 2000 06 00 By briefly pressing the selection key you can visualize the consumption data Consumption results F01 0 00m3 F02 0 00m3 F03 0 00m3 UES 0x0240000000000000 In lines F01 to F03 the current absolute gas consumption values of the relevant...

Страница 5: ...it its pulses the pulses are buffered and will be transmitted afterwards when con sumption is low Pin assignment Pin 1 2 4 6 not connected Pin 3 output Pin 5 output 3 6 4 5 2 1 To connect the pulse output use a socket type IEC 60130 9 Assistance in the event of malfunction Fault Cause Remedy Possible faults and suggested solutions The symbol is displayed If the symbol appears next to a measured va...

Страница 6: ...id 400041 by_class 2 by_ lang 1 Instruction Manual Industrial Diaphragm Gas Meters Type BK G40 BK G65 BK G100 and Type BK G40T BK G65T BK G100T http docuthek kromschroeder com doclib main ph p language 1 folderid 400045 by_class 2 by_ lang 1 ATEX explosion protection The index EI3 is certified as an ATEX subassembly and is marked as follows II 2 G Ex ib IIA T4 Gb Specific explosion protection mark...

Страница 7: ...GB 7 D GB ...

Страница 8: ...ng Limited Paton Drive Tollgate Business Park Beaconside Stafford ST16 3EF T 44 1785 275200 F 44 1785 275305 jeavons info gb elster com www elstermetering co uk Ireland Active Energy Control Ltd Unit 4 Clare Marts Quin Road Ennis Co Clare T 353 65 6840600 F 353 65 6840610 info aec ie www aec ie We reserve the right to make technical modifications in the interests of progress Contact ...

Отзывы: