Elster themis plus Скачать руководство пользователя страница 1

© 2013 Elster GmbH

D

GB

 www.docuthek.com

I

Safety

Please read and keep in a safe place

 Please read through these instructions 

carefully before installing or operating. Following the 
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned 
in accordance with the regulations and standards 
in force. These  instructions can also be found at 
www.docuthek.com.

Explanation of symbols

 • 

,   ,   ,   

... = Action

 

= Instruction

Liability

We will not be held liable for damage resulting from 
non-observance of the instructions and non-com-
pliant use.

Safety instructions

Information that is relevant for safety is indicated in 
the instructions as follows:

 DANGER

Indicates potentially fatal situations.

 WARNING

Indicates possible danger to life and limb.

 CAUTION

Indicates possible material damage.

All interventions may only be carried out by qualified 
gas technicians. Electrical interventions may only be 
carried out by qualified electricians.

Conversion, spare parts

All technical changes are prohibited. Only use OEM 
spare parts.

Transport

On receipt of the product, check that the delivery is 
complete see page 2 (Part designations). Report 
any transport damage immediately. 

Storage

Store the product in a dry place. Ambient tempera-
ture: see page 6 (Technical data).

Changes to edition 08.

The following chapters have been changed:
–  Checking the usage
–  Navigating within the menu

Contents

Operating instructions  

for consumers

Translation from the German

D

GB

F

NL

I

E

GB-1

0500/00 · Edition .

Safety

Contents

Electronic index for  

diaphragm gas meters BK..B

xxxx ivd/Fx xxx

Electronic index for  

diaphragm gas meters BK..B  . . . . . . . . . . . . . 
Contents  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Checking the usage . . . . . . . . . . . . . . . . . . . . . 
Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Operating the electronic index . . . . . . . . . . . . 
Navigating within the menu  . . . . . . . . . . . . . . 
Electrical pulse output. . . . . . . . . . . . . . . . . . . 5

Assistance in the event of malfunction  . . . . . 5

Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . 6

Disposal  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Contact  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Содержание themis plus

Страница 1: ...ns may only be carried out by qualified gas technicians Electrical interventions may only be carried out by qualified electricians Conversion spare parts All technical changes are prohibited Only use OEM spare parts Transport On receipt of the product check that the delivery is complete see page 2 Part designations Report any transport damage immediately Storage Store the product in a dry place Am...

Страница 2: ...for use in po tentially explosive atmospheres For the exact use zone see ATEX sticker on the diaphragm gas meter or see Operating instructions for diaphragm gas meters BK G1 6 to BK G25 http docuthek kromschroeder com doclib main php language 1 folderid 400041 by_ class 2 by_lang 1 Instruction Manual Industrial Diaphragm Gas Meters Type BK G40 BK G65 BK G100 and Type BK G40T BK G65T BK G100T http ...

Страница 3: ...ally The Current meter reading main screen appears when switching on the index If you are in a different menu the display will automatically change back to the main screen when no user key has been pressed for 30 s and switches off after a further 30 s You can navigate from the main screen to the various menus such as Date and time UTC using the user keys Menu overview Current meter reading Genera...

Страница 4: ...ss further information Here the active tariff program is displayed as are the date and time of activation Tariff information ID Green Spring Demo From 01 01 2000 06 00 By briefly pressing the selection key you can visualize the consumption data Consumption results F01 0 00m3 F02 0 00m3 F03 0 00m3 UES 0x0240000000000000 In lines F01 to F03 the current absolute gas consumption values of the relevant...

Страница 5: ...it its pulses the pulses are buffered and will be transmitted afterwards when con sumption is low Pin assignment Pin 1 2 4 6 not connected Pin 3 output Pin 5 output 3 6 4 5 2 1 To connect the pulse output use a socket type IEC 60130 9 Assistance in the event of malfunction Fault Cause Remedy Possible faults and suggested solutions The symbol is displayed If the symbol appears next to a measured va...

Страница 6: ...id 400041 by_class 2 by_ lang 1 Instruction Manual Industrial Diaphragm Gas Meters Type BK G40 BK G65 BK G100 and Type BK G40T BK G65T BK G100T http docuthek kromschroeder com doclib main ph p language 1 folderid 400045 by_class 2 by_ lang 1 ATEX explosion protection The index EI3 is certified as an ATEX subassembly and is marked as follows II 2 G Ex ib IIA T4 Gb Specific explosion protection mark...

Страница 7: ...GB 7 D GB ...

Страница 8: ...ng Limited Paton Drive Tollgate Business Park Beaconside Stafford ST16 3EF T 44 1785 275200 F 44 1785 275305 jeavons info gb elster com www elstermetering co uk Ireland Active Energy Control Ltd Unit 4 Clare Marts Quin Road Ennis Co Clare T 353 65 6840600 F 353 65 6840610 info aec ie www aec ie We reserve the right to make technical modifications in the interests of progress Contact ...

Отзывы: