![Elster Kromschroder VMF 110 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/elster/kromschroder-vmf-110/kromschroder-vmf-110_technical-information_2396799006.webp)
VMF · Edition 02.11
6
2 Function
Base plate
Retaining frame
with strainer
Filter pad
Housing
Pressure test point
Flange
VMF..M with test points
There is a retaining frame with an integrated strainer and filter
pad in the housing of the VMF. The filter pad is supported by
the strainer. The filter pad and the strainer rid the gas of coarse
as well as fine impurities.
In order to replace the filter pad, the two retaining screws are
undone and the base plate removed. The retaining frame with
the filter pad is pulled out. The retaining frame is opened and
the filter pad can be taken out.
The VMF is delivered with two test points for pressure measure-
ment as standard. The VMF can also optionally be delivered
with two 1/8“ screw plugs.
NO
NC
COM
Base plate
Retaining frame
with strainer
Filter pad
Housing
Pressure test point
Pressure switch DG..VC
Flange
VMF..1 to 4 with pressure switch DG..VC
The VMF..1 to 4 is equipped with a pressure switch for moni-
toring minimum or maximum pressure. The pressure switch
monitors the outlet pressure downstream of the filter pad. In
addition, there is also a test point for measuring the pressure