Elster BK Series Скачать руководство пользователя страница 4

GB-4

D

GB

F

NL

I

SK

Date and time: UTC

Information on the date and time display.

The current date and time appears when the 

selection key   is pressed. The time is given in 
UTC format (universal time coordinated) and must 
be adjusted to the local time, see http://www.
worldtimeserver.com/convert_time_in_UTC.aspx 
or http://en.wikipedia.org/wiki/Time_zone#Time_

zone_as_offsets_from_UTC.

Important! Note summer and winter times.

Date and time: UTC

Holt       to return

2010–03–15

03:20:18

The date is given in the format year – month – day.

Past meter readings

Consumption data dating as far back as 20 weeks 
can be called up.

By pressing the selection key  , consumption 
data are displayed, which are given by month, 
week or day, or 4-hour or ½-hour intervals.

“4 hour summary” example:

4 hour summary:  Sat

2010-02-15   00:30

→ 

04:30

00000.351  

→  

00000.353m

3

Tariff band

0.

002

  m

3

The timeframe is displayed with date and time for 

the start and end of the period. The time is given 
in UTC format (universal time coordinated) and 
must be adjusted to the local time.

The meter reading is displayed for the start and 

end of the period in m

3

.

The consumption for this period is indicated in m

3

.

The tariff band may be displayed.

Electronic index with communication module:

The 

 symbol is displayed if, for example, the 

tolerance between the internal time recording 
and the actual time is too large. This can lead to 
invalid consumption data. After the next time syn-
chronization, the consumption data are recorded 
again correctly and 

 disappears.

Tariff totals

If the optional tariff data are configured, they can 
be called up here.

Tariff data with measured gas volumes are dis-

played by pressing the selection key  .

“Previous tariff” example:

Previous tariff

2010-01-01  

→  

2010-03-31

Tariff: Winter (1)

0.

810

  m

3

The timeframe is displayed with the date for the 

start and end of the period.

The selected tariff is displayed.

The consumption for this period is indicated in m

3

.

Text messages

The 

 symbol signals receipt of a new message. 

The message can be called up in this menu.

If the display was switched off and a new mes-
sage was received in the meantime, the message 
will be displayed instead of the basic display when 
the display is switched on again.

When navigating in the menu, the symbol is dis-

played in the main menu.

Opening valve

The 

ON

 symbol appears if the valve or the gas 

flow is open. This symbol is only displayed when 

a valve is integrated in the gas meter.

If the valve was released while the display was 
switched off, the release note will appear the next 
time the index is switched on.

OFF

Opening valve

CECK IF APPLIANCES,

OFF, THEN HOLD

The note remains active until the valve has been 

released.

If the selection key   is not pressed, the display 
will switch back to the basic display after 30 s.

Содержание BK Series

Страница 1: ... Only use OEM spare parts Transport On receipt of the product check that the delivery is complete see Part designations Report any trans port damage immediately Storage Store the product in a dry place Ambient tempera ture see Technical data Translation from the German D GB GB 1 Operating instructions for operators and installers Safety Contents Operating instructions for operators and installers ...

Страница 2: ...5 Service cover 6 Service seal 7 Battery Type label Index plate BK G E DE 07 MI002 PTB001 002545632734 class 1 5 Q max Q min M10 0102 12345678 Installation Installing the gas meter For installing the gas meter in the pipe work refer to the operating instructions for diaphragm gas meters BK G1 6 to BK G25 and BK G1 6T to BK G25T see http docuthek kromschroeder com doclib main php language 1 folderi...

Страница 3: ...n some menus may be missing The Current meter reading basic display appears when switching on the index If you are in a different menu the display will automatically change back to the basic display when no user key has been pressed for 30 s and switches off after a further 30 s You can navigate from the basic display to the various menus such as Meter information using the user keys Menu overview...

Страница 4: ...nce between the internal time recording and the actual time is too large This can lead to invalid consumption data After the next time syn chronization the consumption data are recorded again correctly and disappears Tariff totals If the optional tariff data are configured they can be called up here Tariff data with measured gas volumes are dis played by pressing the selection key Previous tariff ...

Страница 5: ...n the display 2 Briefly press the selection key A further test pattern appears in the display 3 Hold the selection key pressed down The display switches to the previous menu Cyclic test The accuracy of the meter can be checked using a cyclic volume test Cyclic test Starting Cycles 0 0 0000 00 C 00 000000m3 U 00 000000m3 Press to abandon test C volume U volume temperature converted Cycles number of...

Страница 6: ...replaced when the optical communication link has been established see Establishing an optical communication link p 6 Otherwise data will be lost 2 Initiate changing the battery The procedure depends on your user software Attention The battery may only be removed once a release message has been issued by the index As soon as the release message NOW READY TO CHANGE THE BATTERY PACK appears there is ...

Страница 7: ...nufacturer 6 Re seal the service seal Check test The MID 2004 22 EC prescribes that the measur ing instrument in this case the BK should be able to be checked The accuracy of the meter must be checked by comparing the flow rates The requirements and test methods must comply with national laws and regulations The check should be carried out using the cyclic test see Service mode p 5 Assistance in t...

Страница 8: ... Optical interface pursuant to EN 62056 21 Mode E Annex B 2 For further technical data on diaphragm gas meters BK see Diaphragm meters BK G1 6 to BK G25 and BK G1 6T to BK G25T operating instructions http docuthek kromschroeder com doclib main php language 1 folderid 400041 by_class 2 by_ lang 1 Declaration of conformity Diaphragm gas meters BK E with electronic index We the manufacturer hereby de...

Отзывы: