For the compression of seals and the resulting 
tightening torques for the screw unions, the seal 
manufacturers’ specifications must be observed.

 

 Tightening torques for the recommended flat 

seals in conjunction with screw connectors 
pursuant to DIN 3376-1 and 3376-2, see 
www.docuthek.com 

→ 

Elster-Instromet 

→ 

Prod-

ucts 

→ 

Gas measuring devices 

 Diaphragm 

meters 

 Ergänzung für Betriebsanleitung BK, 

Verschraubungen und Anzugsmomente für 

BK-G1,6 bis BK-G25 (Supplement for BK op-
erating instructions, Screw unions and tightening 
torques for BK-G1.6 to BK-G25) (D).

    

Install the gas meter free of mechanical stress.

 

If a pulse sensor IN-Z6x is used for pulse tap-
ping on the gas meter marked with 

 – see 

Data sheet for pulse sensor IN-Z6x (D, GB) 
www.docuthek.com 

→ 

Elster-Instromet 

→ 

Prod-

ucts 

→ 

Gas measuring devices 

 Diaphragm 

meters 

→ 

Pulse sensor IN-Z61 and the stand-

ard EN 60079-14 (Explosive atmospheres).

Temperature test point

 

Temperature sensors can be inserted into the 

thermowells for measuring the gas temperature 
in the meter housing.

1

2

  

 Secure each of the temperature sensors using 

the capstan screw provided.

Connecting the pressure measuring 
line

 WARNING

In order to ensure that the gas meter is tight:

–   The pressure test nipple must not be twisted, 

bent, or otherwise manipulated.

–   When installing, always secure the pressure test 

nipple using a suitable spanner.

 

Functional safety and reliability are ensured only if 
the material combination of the screw connector 
and the pressure line are intermatched.

 

Only use the olive and the attached union nut 
supplied. The olive is secured to the sealing 
sleeve.

 

When re-ordering, use original Parker EO pro-
gressive ring fittings PSR/DPR.

1

6

7

2

3

4

5

 

Use corrosion-resistant, seamless precision 
steel tube pursuant to DIN EN 10305-4 (exter-
nal  diameter 6 mm, material E235 = 1.0308). For 
other materials, use a suitable adapter and note 
the Parker/EO recommendations.

 

Install pipes free of mechanical stress.

1

6

7

2

3

4

5

 8   

Screw on the union nut by hand as far as it will 
go.

 

At the same time, press the end of the pipe firmly 

against the stop.

 9   

Mark the position of the union nut and tighten 
with about 1½ turns.

1

6

7

2

3

4

5

 

When re-installing, the union nut will be turned 
to the original position and then further tightened 
through approx. 30°.

   

Once the installation and tightness test are com-
plete, see page 4 (Tightness test), protect the 
pressure test point against external access with 
the sealing sleeve and the seal.

Tightness test

 

Check the pipework for leaks prior to installation 
of the gas meter, in case the pipework is tested 
with a greater test pressure than the max. al-
lowable operating pressure p

max.

 for the gas 

meter. Otherwise, the installed gas meter may 
be damaged.

 

If a valve is integrated in the diaphragm gas me-
ter BK, see page 2 (Type label/Index plate), this 
must be opened for the tightness test.

 

Ensure the customer’s consumers are closed.

Содержание BK-G1.6

Страница 1: ...changes are prohibited Only use OEM spare parts Transport Diaphragm gas meters are always to be transported in the upright position On receipt of the product check that the delivery is complete see Part desig nations Report any transport damage immediately Storage Diaphragm gas meters are always to be stored in the upright position and in a dry place Ambient tempera ture see Technical data Content...

Страница 2: ...cal index Chekker mechanical index Absolute ENCODER index Electronic index Indication of volume at base conditions T Te Temperature conversion mechanical electronic Part designations 2 1 3 4 6 5 1 Diaphragm gas meter BK 2 Index with index plate 3 Connectors 4 Protective caps 5 2 x thermowells optional 6 Pressure test point with sealing sleeve optional Type label Index plate Diaphragm gas meters BK...

Страница 3: ...gm gas meter BK with integrated valve make sure that no dirt particles get into the meter and thus into the valve The yellow sealing sleeve protects the pressure test point on the gas meter It may only be opened for connecting a pressure measuring line Use seals made from tested materials Elastomer seals or asbestos free flat seals from Elster are recommended For meters resistant to high temperatu...

Страница 4: ...suitable spanner Functional safety and reliability are ensured only if the material combination of the screw connector and the pressure line are intermatched Only use the olive and the attached union nut supplied The olive is secured to the sealing sleeve When re ordering use original Parker EO pro gressive ring fittings PSR DPR 1 6 7 2 3 4 5 Use corrosion resistant seamless precision steel tube p...

Страница 5: ... Smart Metering Diaphragm gas meters BK with integrated valve In the event that the diaphragm gas meter BK is fitted with an integrated valve see page 3 Diaphragm gas meters with integrated valve the gas supply can be connected or disconnected remotely Unless otherwise agreed the valve is open on delivery as standard WARNING The network provider is responsible for the safe remote shut down and res...

Страница 6: ...s permitted see operating instructions for Electronic index for diaphragm gas meters BK E Technical data Diaphragm gas meters BK Gas type natural gas town gas propane and butane as gases of the first to third families pursuant to DIN EN 437 2003 DVGW Code of Practice G260 Max allowable operating pressure pmax see type label index plate Max allowable measuring range Qmin Qmax see type label index p...

Страница 7: ...aminations DE 07 MI002 PTB001 DE 07 MI002 PTB002 The production is subject to the surveillance procedure pursuant to 2004 22 EC Annex D Physikalisch Technische Bundesanstalt German National Metrological Institute Notified Body 0102 Markings M 0102 DE 07 MI002 PTB001 or DE 07 MI002 PTB002 After the M the year of construction is given EMC EC Directive 2004 108 EC EMC Standards OIML D11 2004 Sec 12 E...

Страница 8: ...0610 info aec ie www aec ie Germany Elster GmbH Strotheweg 1 49504 Lotte T 49 541 1214 0 F 49 541 1214 370 info elster instromet com www elster instromet com Contact ATEX legend Marking of explosion protection II Equipment group ll for general industries with the exception of mines 2 Category internal none external Category 2 Zone 1 3 Category internal none external Category 3 Zone 2 G Type of atm...

Отзывы: