Released

 

The “Smart Valve” opens an internal bypass and 

releases a minimum gas flow into the customer’s 
closed consumer piping. Pressure equalization 
takes place between the inlet and outlet side 
of the valve.

Open

 

Following pressure equalization, the valve auto-
matically opens by spring force and fully releases 
the gas supply. If consumers of the customer are 
open, pressure equalization cannot occur and 
the valve remains in the “Released” position and 
continues to release only the minimum gas flow 
rate of the bypass.

Closed

 

The valve and the bypass are closed in the event 

of remote shut-down.

 

All valve positions are kept de-energized.

Maintenance/Removal

Gas meters BK-G1.6 to 25 from Elster are mainte-
nance-free.

 

When used for custody transfer measurements, 

recalibration must be carried out in accordance 
with national directives.

 

If the screw unions are loosened for maintenance 
work or retesting, replace the seals.

 

After the gas meter has been removed, immedi-

ately close the connectors with protective caps, 
in order to prevent an ingress of dirt particles.

 WARNING

A certain amount of gas may remain in the gas 

meter. Taking into consideration the risk of explo-
sion, it is important to adopt safety measures, e.g.:

–  Following removal of the gas meter, purge it thor-

oughly with inert gas.

–  For transporting the gas meter with gas residue, 

use a vehicle with an open or a ventilated loading 
area.

–   The indexes must not be opened in an explosion-

hazard area even for maintenance and repair. 
Opening of the service cover on the electronic 
index, e.g. to change the battery, is permitted – 
see operating instructions for “Electronic index 
for diaphragm gas meters BK..E”.

Technical data

Diaphragm gas meters BK

Gas type: natural gas, town gas, propane and butane, 
as gases of the first to third families pursuant to 
DIN EN 437:2003 (DVGW Code of Practice G260).
Max. allowable operating pressure p

max.

, see type 

label/index plate.
Max. allowable measuring range Q

min.

/Q

max.

, see 

type label/index plate.

Transitional flow rate Q

t

 = 0.1 x Q

max.

.

Max. allowable ambient temperature range t

m

, see 

type label/index plate.
Max. allowable storage temperature range:

-25 to +60°C.

Gas temperature t

g

, where the measuring error still 

lies within the error limits set out in the Directive, see 
type label/index plate. If no gas temperature t

g

 is 

specified on the index plate, t

g

 = t

m

 applies.

Cyclic volume V, see type label/index plate.
Base temperature t

b

 (for meters with temperature 

conversion only), see type label/index plate.
Specified centre temperature t

sp

 (for meters with tem-

perature conversion only), see type label/index plate.
For BK..E.., the cyclic volume V and the specified 
centre temperature t

sp

 are not stated on the index 

plate, but can be called up in the display using the 
menu.

Diaphragm gas meters BK with pressure test 

point

Pressure test point: 24° olive fitting to EN ISO 8434-1, 
L6 x M12 x 1.5-St.

Diaphragm gas meters BK with explosion 

protection

Max. allowable ambient temperature range t

m

/gas 

temperature range t

g

: -25 to +55°C; for constraints, 

see type label/index plate.

Diaphragm gas meters BK with integrated 

“Smart Valve” Vs

Not suitable for highly contaminated gases, e.g. 
town gas.
Opening time from closed to open/released state: 

≤ 4 s,

closing time: ≤ 0.5 s.
Min. operating pressure: 17.5 mbar.

Allowed leakage flow in the customer’s piping: 
valve released: max. 13 l/h at 35 mbar, 
valve closed: max. 5 l/h.

Содержание BK-G1.6

Страница 1: ...changes are prohibited Only use OEM spare parts Transport Diaphragm gas meters are always to be transported in the upright position On receipt of the product check that the delivery is complete see Part desig nations Report any transport damage immediately Storage Diaphragm gas meters are always to be stored in the upright position and in a dry place Ambient tempera ture see Technical data Content...

Страница 2: ...cal index Chekker mechanical index Absolute ENCODER index Electronic index Indication of volume at base conditions T Te Temperature conversion mechanical electronic Part designations 2 1 3 4 6 5 1 Diaphragm gas meter BK 2 Index with index plate 3 Connectors 4 Protective caps 5 2 x thermowells optional 6 Pressure test point with sealing sleeve optional Type label Index plate Diaphragm gas meters BK...

Страница 3: ...gm gas meter BK with integrated valve make sure that no dirt particles get into the meter and thus into the valve The yellow sealing sleeve protects the pressure test point on the gas meter It may only be opened for connecting a pressure measuring line Use seals made from tested materials Elastomer seals or asbestos free flat seals from Elster are recommended For meters resistant to high temperatu...

Страница 4: ...suitable spanner Functional safety and reliability are ensured only if the material combination of the screw connector and the pressure line are intermatched Only use the olive and the attached union nut supplied The olive is secured to the sealing sleeve When re ordering use original Parker EO pro gressive ring fittings PSR DPR 1 6 7 2 3 4 5 Use corrosion resistant seamless precision steel tube p...

Страница 5: ... Smart Metering Diaphragm gas meters BK with integrated valve In the event that the diaphragm gas meter BK is fitted with an integrated valve see page 3 Diaphragm gas meters with integrated valve the gas supply can be connected or disconnected remotely Unless otherwise agreed the valve is open on delivery as standard WARNING The network provider is responsible for the safe remote shut down and res...

Страница 6: ...s permitted see operating instructions for Electronic index for diaphragm gas meters BK E Technical data Diaphragm gas meters BK Gas type natural gas town gas propane and butane as gases of the first to third families pursuant to DIN EN 437 2003 DVGW Code of Practice G260 Max allowable operating pressure pmax see type label index plate Max allowable measuring range Qmin Qmax see type label index p...

Страница 7: ...aminations DE 07 MI002 PTB001 DE 07 MI002 PTB002 The production is subject to the surveillance procedure pursuant to 2004 22 EC Annex D Physikalisch Technische Bundesanstalt German National Metrological Institute Notified Body 0102 Markings M 0102 DE 07 MI002 PTB001 or DE 07 MI002 PTB002 After the M the year of construction is given EMC EC Directive 2004 108 EC EMC Standards OIML D11 2004 Sec 12 E...

Страница 8: ...0610 info aec ie www aec ie Germany Elster GmbH Strotheweg 1 49504 Lotte T 49 541 1214 0 F 49 541 1214 370 info elster instromet com www elster instromet com Contact ATEX legend Marking of explosion protection II Equipment group ll for general industries with the exception of mines 2 Category internal none external Category 2 Zone 1 3 Category internal none external Category 3 Zone 2 G Type of atm...

Отзывы: