background image

GB-3

D

GB

F

NL

I

SK

BK-G..E and BK-G..B

The following data is not specified on the type label/

index plate, but can be called up in the menu:

–   specified centre temperature t

sp

 (for meters with 

temperature conversion only),

–   EN 1359 registration number (if available),
–   firmware  version.

Diaphragm gas meters with integrated valve

DE-07-MI002-PTB001
002545632734

class 1,5

NG-47001BM0443 DIN EN 1359:2007

BK-G..

 

VALVE Vx

M12  0102

m

3

,

-

Valve variants:
Vs = Smart Valve
Vp = bi-stable valve (prepayment meter)
Ve = bi-stable valve for electronic index

 

Up to 12.2011, all valve versions were simply 
marked with the word VALVE on the type label/
index plate.

ATEX identification

BK-G..M, BK-G..C, BK-G..MT, BK-G..CT

BK

Elster GmbH, Strotheweg 1

D-49504 Lotte, Germany

TÜV 11 ATEX 090370 X

II -/2 G c IIB TX

Use as follows:
Category: internal: none, external: Category 2 (Zone 1).

Type of atmosphere: gases, hazes and vapours.

Diaphragm gas meters BK-G..A, BK-G..AT

BK

Elster GmbH, Strotheweg 1

D-49504 Lotte, Germany

Ui=5,5V   Ii=30mA   Pi=33mW    Ci=140

µ

F   Li=0

µ

F

II -/2 G IIB T4

Use as follows:
Category: internal: none, external: Category 2 (Zone 1). 

Type of atmosphere: gases, hazes and vapours.

Diaphragm gas meters BK-G..E, BK-G..ET, 

BK-G..ETB

BK

Elster GmbH, Strotheweg 1

D-49504 Lotte, Germany

TÜV 11 ATEX 093627 X

II -/3 G IIA T1

Use as follows:
Category: internal: none, external: Category 3 (Zone 2).

Type of atmosphere: gases, hazes and vapours.

Diaphragm gas meters BK-G..B

BK

Elster GmbH, Strotheweg 1

D-49504 Lotte, Germany

TÜV 12 ATEX 098560 X

II -/2 G IIA T4

Use as follows:
Category: internal: none, external: Category 2 (Zone 1).

Type of atmosphere: gases, hazes and vapours.

Installation

 WARNING

Please observe the following to ensure that neither 
persons nor the gas meter are damaged during 
installation and operation:

–   Note the max. allowable operating pres-

sure p

max

 and measuring range Q

max

, see 

page 2 (Type label/Index plate).

–   Note the permitted ambient temperature t

m

 and 

gas temperature t

g

, see page 2 (Type label/

Index plate) or page 7 (Technical data).

–   The gas meter is suitable for mechanical ambient 

conditions of Class M1 of Directive 2004/22/EC. 
For gas meter versions BK..A, BK..E and BK..B, 
Class E2 for electromagnetic ambient conditions 
also applies.

–   When installing the diaphragm gas meter BK 

with integrated valve, make sure that no dirt 
particles get into the meter and thus into the 
valve.

–   The yellow sealing sleeve protects the pres-

sure test point on the gas meter. It may only be 
opened for connecting a pressure measuring 
line.

–   Use seals made from tested materials.  Elastomer 

seals or asbestos-free flat seals from Elster are 
recommended.

–   For meters resistant to high temperatures, only 

use seals tested to be resistant to high tempera-
tures.

–   Only use the seals once.
–   For installation and operation, note the applica-

ble national regulations and the directives of the 
gas supply company. For Germany, the valid 
DVGW Code of Practice G600 (DVGW-TRGI) 
applies.

–   Work on meters and the installation of meters 

which are marked with 

 and are installed in 

potentially explosive atmospheres may only be 
carried out by persons with appropriate qualifi-
cations.

Содержание BK-G Series

Страница 1: ...transported in the upright position On receipt of the product check that the delivery is complete see Part desig nations Report any transport damage immediately Storage Diaphragm gas meters are always to be stored in the upright position and in a dry place Ambient tempera ture see Technical data Changes to edition 05 13 The following chapters have been changed Checking the usage Commissioning Main...

Страница 2: ...hekker mechanical index Absolute ENCODER index Electronic index Indication of volume at base conditions T Te TB Temperature conversion mechanical electronic mechanical electronic temperature conversion and pressure correction Part designations 2 1 3 4 6 5 1 Diaphragm gas meter BK 2 Index with index plate 3 Connectors 4 Protective caps 5 2 x thermowells optional 6 Pressure test point with sealing s...

Страница 3: ...ermany TÜV 12 ATEX 098560 X II 2 G IIA T4 Use as follows Category internal none external Category 2 Zone 1 Type of atmosphere gases hazes and vapours Installation WARNING Please observe the following to ensure that neither persons nor the gas meter are damaged during installation and operation Note the max allowable operating pres sure pmax and measuring range Qmax see page 2 Type label Index plat...

Страница 4: ...Anzugsmomente für BK G1 6 bis BK G25 Supplement to BK operating instructions Screw unions and tightening tor ques for BK G1 6 to BK G25 D 2 Install the gas meter free of mechanical stress If a pulse transmitter IN Z6x is used for pulse tapping on the gas meter marked with see Data sheet for pulse transmitter IN Z6x D GB www docuthek com Elster Instromet Prod ucts Gas measuring devices Diaphragm me...

Страница 5: ...g the pulse transmitter IN Z6x can be connected see Data sheet for pulse transmitter IN Z6x D GB www docuthek com Elster Instromet Products Gas measuring devices Diaphragm meters Pulse transmitter IN Z61 BK G A with Absolute ENCODER index AE1 Z6 Interface description for gas meters with ENCODER index see Specification GB www docuthek com Elster Instromet Products Archive Gas measuring devices BK G...

Страница 6: ...eleases the gas supply If consumers of the customer are open pressure equalization cannot occur and the valve remains in the Released position and continues to release only the minimum gas flow rate of the bypass Closed The valve and the bypass are closed in the event of remote shut down All valve positions are kept de energized Maintenance Removal Gas meters BK G1 6 to 25 from Elster are mainte n...

Страница 7: ...i 30 mA Pi 33 mW Ci 140 µF Li 0 µH Diaphragm gas meters BK with integrated valve Vp Opening time 4 s Closing time 0 5 s Max operating pressure 100 mbar Leakage flow closed max 5 l h The specified leakage flow rate is also complied with at pressures 100 mbar e g in the event of a fault Diaphragm gas meters BK with integrated Smart Valve Vs Not suitable for highly contaminated gases e g town gas Ope...

Страница 8: ...ische Bundesan stalt German National Metrological Institute Notified Body 0102 Markings M 0102 DE 11 MI002 PTB001 After the M the year of construction is given EMC EC Directive 2004 108 EC EMC Standards OIML D11 2004 Sec 12 EN 55022 2006 A1 2007 ETSI EN 301 489 17 V2 1 1 ETSI EN 301 489 1 V1 8 1 Tests and inspections EMC Test NRW GmbH Test Report No P10 Z 00086 002 P13 Z 00096 001 TRaC Global Ltd ...

Страница 9: ...en EMC EC Directive 2004 108 EC EMC Standards EN 55022 2006 A1 2007 Class B EN 61000 4 2 2009 EN 61000 4 3 2006 A1 2008 A2 2010 EN 61000 4 4 2004 A1 2010 EN 61000 4 5 2006 EN 61000 4 6 2009 EN 61000 4 12 2006 EN 61000 4 8 2010 IEC 61000 6 3 2006 Class B Tests EMV Testhaus GmbH Test Report No 120393 AU01 E01 NMi Certin B V Test Report NMi 12200781 03 R TTE EC Directive 1999 5 EC R TTE Standards EN ...

Страница 10: ...eaconside Stafford ST16 3EF T 44 1785 275200 F 44 1785 275305 jeavons info gb elster com www elstermetering co uk Ireland Active Energy Control Ltd Unit 4 Clare Marts Quin Road Ennis Co Clare T 353 65 6840600 F 353 65 6840610 info aec ie www aec ie Germany Elster GmbH Strotheweg 1 49504 Lotte T 49 541 1214 0 F 49 541 1214 370 info elster instromet com www elster instromet com Contact ...