4 Air control
A central protective system such as the FCU 500 takes over
air control. It monitors the static air pressure as well as the air
volume required for pre-purge, start-up and after the furnace
has been shut down. The air actuators (BCU..F1 = actuators
IC 20/40, BCU..F2 = RBW actuators, BCU..F3 = valve) are actu-
ated for this purpose by the capacity control system of the BCU.
After being enabled by the protective system, the BCU can
start the burners. The capacity is controlled during operation
by an external temperature control system.