32
Installation
, connection and commissioning
To adopt the value set, move the cursor to the
Store
value.
Press the key combination ENTER
+
"0" flashes.
Change the value using the arrow buttons
or
to "1".
After the value has been changed, press the key combination ENTER
+
in order
to confirm the input. It is possible to abort the entry by pressing the key combination
ESC
+
.
For
Vb
,
VbA
is adopted.
If the administrator lock is open and the transfer of VbA for Vb is rejected with the
–13– message then this process has already been carried out.
Further changes are possible when either the calibration lock or the
administration lock is open, after deleting the change information regarding
setting Vb (see chapter 0).
5.3.1.6 Deleting change information for alignment of Vb
To allow for resetting of the standard volume when the administrator lock is open, the change
information regarding setting at the same value as
"Vb"
must be deleted:
Open the calibration lock
Move the cursor to the "Serv." tab and via the following path to the value "Clear"
(adjustable volume at base conditions) input mode:
Serv.
Volume
Standard volume
Synchronization Vb
Clear
Press the key combination ENTER
+
"0" flashes.
Change the value using the arrow buttons
or
to "1".
After the value has been changed, press the key combination ENTER
+
in order
to confirm the input. It is possible to abort the entry by pressing the key combination
ESC
+
.
"
TimeX
" (time stamp of the alignment), "
Vb_o
" (Vb old value), "
Vb_n
"
(Vb new value) are set to the default values.
5.3.1.7 Setting compressibility equation and gas analysis
Move the cursor to the "Serv" tab and via the following path to the value "
Md.K
"
(compressibility equation) input mode:
Serv.
Volume conversion
Parameter settings
Md.K
Press the key combination ENTER
+
The value set flashes.
Change the value using the arrow buttons
or
. In doing so, observe the legal
provisions applicable at the place of use.
Md.K
Meaning
Fixed value
No calculation of the compressibility. The adjustable K.F value is
used.
S-Gerg-88
Calculation of the compressibility in accordance with S-Gerg-88
AGA-NX19
Calculation of the compressibility in accordance with AGA-NX19
AGA-8 GC1
AGA8 gross characterization method 1
AGA-8 GC2
AGA8 gross characterization method 2
AGA-NX19-HW
AGA-NX19 according to Herning and Wolowsky
AGA-8 DC92
AGA8 detailed characterization
Содержание EK205
Страница 1: ...Operating manual Volume conversion device EK205 ...
Страница 6: ......
Страница 64: ...64 Appendix 9 2 Conformity declarations19 19 IECEx is not available for all device types ...
Страница 65: ...Appendix 65 9 3 Design test certifications 9 3 1 ATEX EC Type Examination Certificat ...
Страница 66: ...66 Appendix ...
Страница 67: ...Appendix 67 ...
Страница 68: ...68 Appendix 9 3 2 IECEx Certificate of Conformity20 20 Not available for all device types ...
Страница 69: ...Appendix 69 ...
Страница 70: ...70 Appendix ...
Страница 71: ...Appendix 71 ...