Installation
4
Page 22 of 38
Safety Instructions
UFM Series 6
4.6 Pressure Connection
All forged meters bodies sizes 3” (DN80) to 12” (DN300) are supplied with
½” NPT Pr adapters and ½” NPT blind plugs. Adapters and plugs are sealed
with PTFE tape and hydrotested with the meter body. After the hydrotest,
adapters and plugs are painted together with the meter body. Where
necessary, seals on Pm (Pr) point adapter (at both ends) and the blind plug
should be replaced with appropriate sealant for the application. Hold the Pr
point adapter with a 30mm wrench while removing the blind plug or fitting
new connections.
4.7 Maintenance
For maintenance refer to the UFM Series 6 Operation and Maintenance
Manual for your particular meter (latest valid revision).
Please see
for a complete list of resources.
Attention!
ALWAYS CHECK NEWLY MADE CONNECTIONS FOR LEAKS.
Please see
These places need to be checked
for leaks, when new Pressure
connection has been made.
These places need to
be checked for leaks
when a new pressure
connection has been
made.
Figure 4-3: Example of Pressure connection with Pressure Adapter