5
Characteristics
TECHNICAL DATA
Code
HPN2L
DEMI
HPN3L
DEMI
HPN4L
DEMI
HPN5L
DEMI
HPN6L
DEMI
HPN7L
DEMI
HPN8L
DEMI
HPN9L
DEMI
HPN11L
DEMI
HPN14L
DEMI
SPRAY PRODUCTION
Max. Capacity
[l/h]
120
180
240
300
360
420
480
540
660
840
Max Pressure
[Mpa/bar
]
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
8/80
DISTRIBUTON RACK
Code
HPN2RA
CKxxx
HPN3RA
CKxxx
HPN4RA
CKxxx
HPN5RA
CKxxx
HPN6RA
CKxxx
HPN7RA
CKxxx
HPN8RA
CKxxx
HPN9RA
CKxxx
HPN11R
ACKxxx
HPN14R
ACKxxx
Max. Nozzles
(8l/h)
[n]
15
22
30
37
45
52
60
67
82
105
ELECTRICAL CONNECTIONS
Power [kW]
[kW]
1.5
1.5
1.5
1.5
1.5
1.5
2.2
2.2
4
4
Phases
[Vac, Hz]
1
3
Voltage
[n]
230V, 50/60Hz
400V, 50/60Hz
HYDRAULIC CONNECTIONS
Inlet water quality
---
Supply water shall comply with microbiological requirements of the German Drinking Water
Ordinance (TrinkwV). Supply water must be totally or partially demineralized by drinking water.
Should the unit be installed using normal water, the installer must use a VDI 6022 non-return
valve to be still compliant.
Inlet water
conductivity
μS*cm
0...100
Inlet water
hardness
°F
0...5
Input Pressure
[MPa/ba
r]
0,02...0,7 / 0,2...7
Water inlet
connection
---
M 3/4"GAS
Water drain
connection
---
M 1/4"GAS
HUMIDIFIER CONTROL
Control
---
Integrated on hydraulic module, remote on distribution rack
Control Signals
---
4…20mA (internal controller), 0-10V or ON-OFF (external signal)
MECHANICAL DATA
Dimensions
(WxHxD
[mm])
515x480x335
615x480x335
Weight (kg)
[kg]
50
IP protection
(Main Unit)
---
20
IP protection
(Distribution Rack)
---
40
Droplet Separator
HPNDROPxxx (optional)
CONFORMITY
CE
---
√
√
√
√
√
√
√
√
√
√
VDI6022
---
√
√
√
√
√
√
√
√
√
√