3
Table: Technical parameters in accordance with European Commision regulations
814/2013 and 812/2013
3.0 INSTALLATION
3.1 LOCATION
3.1.1 Inlet must always be on the right.
3.1.2 The outlet of this water heater acts as a vent and must not be blocked or
restricted in any way.
3.1.3 Only use Elson open outlet spouts.
3.1.4 The installation must be carried out in accordance with the relevant
requirements of the appropriate Building Regulations. Either The Building
Regulations, The Building Regulations (Scotland), The Building Regulations
(Northern Ireland), The Water Fittings Regulations or Water Byelaws in
Scotland.
3.1.5 Select a suitable site but check that:
a) There is enough clearance under the heater to allow removal of the element
plate (210mm).
b) When using the outlet spout, it will swing over the sink (or sinks) to be
supplied.
c) There are no hidden services where the wall is to be drilled.
3.1.6 Mark the position of the fixing holes (as shown in figure 01).
3.1.7 Drill and plug the hole positions.
3.1.8 Screw in the top two screws leaving heads 3mm from the wall.
3.1.9 Hang the heater on the two top screws.
3.1.10 Screw in bottom screw to secure heater.
3.1.11 The water heater is designed to be connected directly to the mains via the
valve provided.
It is recommended that a WRAS listed isolating valve (not supplied) be fitted in
the water supply pipe to the heater to allow for servicing.
3.1.12 To remove the terminal cover use a large flat bladed screwdriver to relieve the
snaps located towards the front of the terminal cover at either side. Gripping
the cover at the front, pull downwards.
3.1.13 To fit the cover, locate the hinge at the back. Slide the snaps into place. Apply
Direct
Supplier’s name or trade mark
ELSON
Supplier’s model identifier
EOS7
Storage volume V in litres
7.0
Mixed water at 40 °C V40 in litres
9
The declared load profile
XXS
The water heating energy efficiency class of the model
C
The water heating energy efficiency in %
31.4
The annual electricity consumption in kWh
587
Daily fuel consumption Q fuel in kWh
2.850
The thermostat temperature settings of the water heater, as placed on the market by the
supplier
60°C
Specific precautions that shall be taken when the water heater is assembled, installed or
maintained and disposed of at end of life
See Section 2 to 5