manualshive.com logo in svg
background image

WS1000 Connect assembly

1

WS1000 Connect assembly

 • Version: 07.09.2021 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • 

Technical Service: +49 (0) 7033 / 30945-250

Assembly - Brief instructions

WS1000 Connect controls

Article numbers 60241-60246

Attention, mains voltage! 
VDE (German Association of Electricians) regulations are to 
be observed. Installation, checking, commissioning and

troubleshooting the device may only be performed by
skilled electricians (pursuant to VDE 0100).

Notes on wireless equipment

When planning facilities with devices that communicate via radio, adequate radio
reception must be guaranteed.  The range will be limited by legal regulation and
structural circumstances. Avoid sources of interference and obstacles between re-
ceiver and transmitter, that could disturb the wireless communication. Those
would be for example:

Walls and ceilings (especially concrete and solar protection glazing).

Metal surfaces next to the wireless participants (e. g. aluminium 
construction of a conservatory).

Other wireless devices and powerful local transmitters (e.g. wireless 
headphones), which transmit on the same frequency. Please maintain a 
minimum distance of 30 cm between wireless transmitters for that reason.

Preparing the installation location

The device must only be installed and operated in dry, indoor spaces. 
Avoid condensation.

Concealed box cut-out dimensions: 

W = 248 mm +1 -0
H = 165 mm +1 -0
D = 84 mm

Preparing the control unit

The 

WS1000 Connect assembly

 is delivered assembled. Therefore, the device

first has to be dismantled. After installing the concealed box the electrics, the de-
vice is reassembled in the reverse order.

When handling the display unit, take care with the loudspeaker (1). It is connected
magnetically and with thin, sensitive wires.

For maintenance, the covers can be carefully pried out in order to access the
screws.

BEWARE!
Mains voltage!

Beneath the safety cover there are unprotected live components.

Store the circuit board in a location protected against dirt. 

It must never be ex-

posed to dust or moisture!

Mounting on the wall

Cavity wall installation

The bag with the installation screws is in the concealed box for the controls when
delivered.

Connection and installation of the control unit 

For the electrical installation, guide all the connection cables through the lower or
upper side wall into the concealed box. Keep the connection wires short here to
prevent loops.

After installation of the concealed box, screw the circuit board back in. Connect the
power supply, weather station, display, network and all devices, motors, buttons,
etc. (step 6 and chapter 

Structure of the connection board

). 

WARNING!
Danger from electrical voltage (mains voltage)! 

The concealed box contains uncovered live components.

Attach safety cover before the controls are commissioned.

Pass the display cable through the square cut-out of the black support plate and
screw the plate to the concealed box (step 4). The screws must grip securely into
the threads of the concealed box in order to support the display unit.

Cover the support plate screw connection with the caps provided.

Connect the display unit (step 3).

Hang the display unit at the top of the support plate and fold it down (step 2). The
display snaps in but also has to be secured with 2 screws (step 1).

Structure of the WS1000 Connect connection board

*Power supply to the indoor sensor

The indoor sensor can be powered with +12 V DC via the multifunction inputs:
No. 21, terminal 1(+), 2(-) | 4(+), 5(-) 
No. 23, terminal 3(+), 4(-) | 6(+), 7(-) 
total maximum 400 mA

Structure of the WS1000 Connect PF (potential-free) connection 

board 

*Power supply to the indoor sensor

The indoor sensor can be powered with +12 V DC via the multifunction inputs:
No. 19, terminal 1(+), 2(-) | 4(+), 5(-) 
No. 21, terminal 3(+), 4(-) | 6(+), 7(-) 
total maximum 400 mA

Separate installation of display and power electronics

The display with support panel and power electronics can be installed at separate
locations, for example if the power electronics are to be houses in a distribution
cabinet. Install the power electronics correctly, e.g. in the concealed box and with
the cover provided.

In order to install the display without the concealed box, place two standard
switch boxes at a normal distance above each other (71 mm). The support panel
is mounted on top so that the round cut-outs in the panel sit over the sockets. The
loudspeaker then sinks into the lower socket.

DANGER!
Danger to life from electrical voltage (mains voltage)! 

If the display unit is installed separately, unshielded

components are in the installation sockets. Voltage
can jump to the device if these components come
into contact with defectively insulated cables.

Mains voltage cables in the sockets must have stronger
insulation (coat undamaged).

Use the support panel as a drill template. Place it over the position of the two stan-
dard switch boxes and mark the 4 drill holes for the 4 fixing screws. Use suitable
fastening material (anchors) for the base.

To connect the display and power electronics, a Cat.6A network cable is used, the
shield of which is branched and whose cross section is at least AWG28. The con-
nection cable must not be more than 10 m long.

The manual with additional information about commissioning,
functions and use of the controls 

WS1000 Connect

 can be

downloaded from www.elsner-elektronik.de in the menu area
"Service/Downloads".

Step 1

 Display from below

The display unit is screwed to the sup-
port plate from below. Loosen the
screws.

Step 2

 Display from the side

Hold the lower section of the display
unit and pull forwards, and hang it on
the upper edge.

The display can now be removed. 

Caution! The display is connected
to the connection board in the
concealed box by a cable.

1

2

Display from above

Detailed view: Notices
and mounts of the dis-
play unit.

Step 3

 Display reverse

Loosen the cable connection between
the display unit and circuit boards.

1 Loudspeaker
2 Socket without function (only for 

KNX-capable model)

1

2

Step 4

 Support plate on concealed 

boxes

Remove the support plate from the
concealed box. To do this, loosen the
4 screws.

Support plate on concealed box

After commissioning

 the screws

should be covered with the supplied
covers.

Step 5

 Concealed box with safety co-

ver

The safety cover in the concealed box
is fastened with four screws. Loosen
the screws and remove the cover.

Step 6

 Concealed box with circuit 

board

Remove the circuit board to install the
concealed box.

Step 7

 Concealed box

Place the concealed box in the wall so
that the arrow points up.

Step 8a

 Concealed box with plaster-

board

For plastering, screw the plaster cover
(board) to the concealed box using the
enclosed screws. As a result, the box
moves less when plastered over.

Step 8b

 Cavity wall installation faste-

ning screws

Clamp the concealed box to the wall
using the four enclosed screws. 

or

20

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

21

22

23

24

25

26

27

28

1 Multifunction output 1 

(potential-free)

2 Multifunction output 2 (pot.free)
3 Multifunction output 3 (pot.free)
4 Multifunction output 4 (pot.free)
5+6Outer conductor L1
7-11Motor group 1-5
12-16Motor group 6-10

17 Mains connection

 L/N/PE 230 V/

50 Hz

18 Wall sensor 1 (terminal 1-3),

2 (terminal 4-6), 3 (terminal 7-9),
4 (terminal 10-12)

19 Wall sensor 5 (terminal 1-3),

6 (terminal 4-6), 7 (terminal 7-9),
8 (terminal 10-12)

20 Wall sensor 9 (terminal 1-3),

Wall sensor 10 (terminal 4-6)

21*Multifunction input 1 (terminal 1-3),

MF input 2 (terminal 4-6)

22 Weather station 

 (terminal 1-2)

Wire assignment: red = 1, black = 2,
yellow and white = not connected

23*Multifunction input 3 (terminal 3-5),

MF input 4 (terminal 6-8)

24 Socket connection display unit 

 

(with power cable)

25 Socket for network connection 

(LAN)

26 Micro-fuse T6,3 A (motor 1-5)
27 Micro-fuse T6,3 A (motor 6-10)
28 Micro-fuse T630 mA

18

1

2

3

4

5

6

7

10

11

12

13

14

15

16

17

19

20

21

22

23

24

8

9

1 Multifunction output 1 

(potential-free)

2 Multifunction output 2 (pot.free)
3 Multifunction output 3 (pot.free)
4 Multifunction output 4 (pot.free)
5-9Motor group 1-5
10-14 Motor group 6-10

15 Mains connection

 L/N/PE 230 V/

50 Hz

16 Wall sensor 1 (terminal 1-3),

2 (terminal 4-6), 3 (terminal 7-9),
4 (terminal 10-12)

17 Wall sensor 5 (terminal 1-3),

6 (terminal 4-6), 7 (terminal 7-9),
8 (terminal 10-12)

18 Wall sensor 9 (terminal 1-3),

Wall sensor 10 (terminal 4-6)

19*Multifunction input 1 (terminal 1-3),

MF input 2 (terminal 4-6)

20 Weather station 

 (terminal 1-2)

Wire assignment: red = 1, black = 2,
yellow and white = not connected

21*Multifunction input 3 (terminal 3-5),

MF input 4 (terminal 6-8)

22 Socket connection display unit 

 

(with power cable)

23 Socket for network connection 

(LAN)

24 Micro-fuse T3,1 A

All dimensions in mm