manualshive.com logo in svg
background image

 

 

Actuators  
KNX S-B2-UP 230 V and 
KNX S-B2-UP 24 V 

 

 

 

 

 

 

        

 

 

 

 

 

 

 

 

Technical Data  

and Installation Notes 

 

 

Elsner Elektronik GmbH

 Steuerungs- und Automatisierungstechnik 

Herdweg 7  • D-75391 Gechingen • Germany 
Phone: +49 (0) 70 56/93 97-0 • Fax: +49 (0) 70 56/93 97-20 

[email protected] • www.elsner-elektronik.de 

Содержание KNX S-B2-UP 230 V

Страница 1: ...UP 24 V Technical Data and Installation Notes Elsner Elektronik GmbH Steuerungs und Automatisierungstechnik Herdweg 7 D 75391 Gechingen Germany Phone 49 0 70 56 93 97 0 Fax 49 0 70 56 93 97 20 info elsner elektronik de www elsner elektronik de ...

Страница 2: ...tomatic Setting of the priority of manual or automatic control by time or via communication object Mutual locking of two drives by means of zero position sensors avoids collisions e g of shading and window master slave Blocking objects and alarm messages have different priority so that safety functions always are higher ranking e g wind blocking Configuration is accomplished by means of the KNX so...

Страница 3: ...owing standards have been considered for the evaluation of the product in terms of electro magnetic compatibility Transient emissions EN 60730 1 2000 Section EMV 23 26 H23 H26 threshold category B EN 50090 2 2 1996 11 A1 2002 01 threshold category B EN 61000 6 3 2001 threshold category B Interference resistance EN 60730 1 2000 Section EMV 23 26 H23 H26 EN 50090 2 2 1996 11 A1 2002 01 EN 61000 6 1 ...

Страница 4: ... B2 UP 230 V AC Fig 1 Front side of KNX S B2 UP 230 V 1 Connecting plug terminal binary inputs only 1 4 from left active 2 Programming LED 3 Programming key PRG 4 Inscription space 5 KNX plug terminal Fig 2 Rear side of KNX S B2 UP 230 V 1 Connecting plug terminal for voltage supply and drive mechanism 2 Microfuse T6 3 A ...

Страница 5: ...uator KNX S B2 UP 24 V DC Fig 3 Front side of KNX S B2 UP 24 V 1 Connecting plug terminal binary inputs only 1 4 from left active 2 Programming LED 3 Programming key PRG 4 Inscription space 5 KNX plug terminal Fig 4 Rear side of KNX S B2 UP 24 V 1 Connecting plug terminal for voltage supply and drive mechanism ...

Страница 6: ...supposedly not be guaranteed the device must be put out of operation and be secured against accidental operation The actators must only be operated as stationary system i e only in a fitted state and after completion of all installation and start up works and only in the environment intended for this purpose Elsner Elektronik does not assume any liability for changes in standards after publication...