elsner elektronik IMSG-UC-4H Скачать руководство пользователя страница 2

Motor control unit IMSG-UC-4H

2

Motor control unit IMSG-UC-4H

 • Version: 28.05.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • 

Technical Service: +49 (0) 7033 / 30945-250

Control with 230V

Connection example with several groups

2.4. Notes on mounting and commissioning

Device must not be exposed to water (rain). This could result in the electronic
being damaged. A relative air humidity of 95% must not be exceeded. Avoid bede-
wing.

Pay attention to the correct connection. An incorrect connection can lead to dama-
ge to the motor control unit or to any electronic device connected to it.

3.

Operation

3.1. Central operation

The central input of the 

IMSG-UC-4H

 allows, for example, an automatic control

unit, a timeswitch or a normal, unlocked double button (Up/Down) to be connec-
ted. The central command (continuous voltage) always has priority over a move-
ment command from the extension inputs.

LED signals during central control (continuous voltage):

If there are "Up" and "Down" movement commands at the central input at the same
time, the drive moves up (secure position).

Set operating mode

The central control unit can be set to the operating modes "Latch" (defaulft) or "De-
adman". You can switch between the operating modes using the following buttons
integrated on the device:

If the 

Latch mode

 is active, the 

Network LED is on

.

If the 

Deadman mode

 is active, the 

Network LED flashes

 every second.

Change the operating mode by pressing

 

 

(channel 1) and

   

(channel 2) again.

3.2. Individual operation

Manual individual operation of the drives can take place via the integrated Up/
Down buttons at the device or via unlocked double buttons (extension inputs). The
movement mode can be stopped via both buttons (

 

or

 

), regardless of the cur-

rent direction of movement.

LED signals during manual control:

Manual operation can be set to "Standard mode" or "Comfort mode":

3.2.1. Standard mode (default)

If a button is pressed for less than 1 second, the drive will move in a step-by-
step fashion. This allows, for example, slats to be positioned precisely. 

If a button is held for longer than 1 second, the drive moves to its final 
position (switching off after 240 seconds of maximum runtime)

This is how you set the Standard mode:

Press the

 

 

button on the channel to be set for 5 seconds and then 

additionally the 

 

button for longer than 1 second

To confirm the On LED on the channel flashes 5 times

3.2.2. Comfort mode

If a button is held for less than 0.3 seconds, the drive moves to its final 
position (switching off after 240 seconds of maximum runtime)

If a button is held for longer than 0.3 seconds, but less than 2 seconds, the 
drive moves only while the button is pressed and stops immediately when 
it is released (deadman function)

If a button is held for longer than 2 seconds, the drive moves to its final 
position (switching off after 240 seconds of maximum runtime)

This is how you set the Comfort mode:

Press the

   

button on the channel to be set for 5 seconds and then 

additionally the

 

 

button for longer than 1 second

To confirm the Off LED on the channel flashes 5 times

3.3. Individual movement position

The 

IMSG-UC-4H

 can store one movement position for each connected drive.

This allows fast and uncomplicated movement to a position that is needed often
(e.g. a shutter position or the partial opening of a window).

3.3.1. Storing a movement position

Storing a position is carried out as follows:

Move the drive to the starting/zero position, i.e. close the window, retract the 
awning or raise the blinds

Press the

 

 

and

   

buttons for three seconds at the same time

As feedback the drive moves briefly up and down. You are in now 
Programming mode

Move to the desired position

Store the position by pressing the

 

 

and

   

buttons for 1 second long at the 

same time

As feedback the drive moves briefly up and down

With blind slats, now open the slats to the desired angle. With awnings, 
tighten the canvas with

 

. For windows, you can skip this point.

Store by again pressing the

 

 

and

   

buttons for 1 second long at the same 

time

As feedback the drive moves briefly up and down. The storage is complete 
and the 

IMSG-UC-4H

 is again in normal mode

Note: As soon as a central command arrives (e.g. because of a wind or rain alarm),
the Programming mode will be interrupted! In this case, please carry out the posi-
tion storage again when the central command is no longer present.

3.3.2. Calling up a movement position

The stored position can be called up by pressing the

 

 

button of the appropriate

channel for 3-6 seconds. 

The drive will move to the movement position directly if it is in a secure position
and the runtimes of previous commands have expired. If the drive is in an interme-
diate position, it will move initially to the secure position and then to the stored po-
sition after expiry of the runtime.

4.

Disposal

After use, the device must be disposed of or recycled in accordance with the legal
regulations. Do not dispose of it with the household waste!

Fig. 2

Each terminal contact may be loaded with a 
maximum of 10 A.

During movement:

Channel LEDs in the direction of movement flash every 2 
seconds

Runtime reached:

Channel LEDs in the direction of movement continue to flash 
every 2 seconds

Fig. 3
For IMSG-UC-2H 
and/or -4H

Each terminal contact may 
be loaded with a maximum 
of 10 A.

Fig. 4
Press the

 

 

button of channel 

1 and the

   

button of channel 

2 for 5 seconds at the same 
time

During movement:

Channel LED in the direction of move-
ment flashes every second

Runtime reached without interruption:

LED for the direction travelled remains on

Intermediate position reached:

LEDs off

Отзывы: