Automatic settings
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
Power failure, maintenance works, etc. (restart of control)
If a power outage occurs, the control unit can no longer control the connected drives!
If the functional scope must be guaranteed even during a power cut, an emergency
power unit with a corresponding switch from network power to emergency operation
should be installed by the customer.
Settings saved in the control unit programme will be maintained even during a power
outage.
Note:
After every re-start (e. g. return of voltage after mains failure or manual reset)
all drives and devices with active automatic reset are in automatic mode.
If cleaning or maintenance work is to be carried out in the conservatory/building, the
control unit should be de-energised and secure against restart by disconnection of the
customer-installed fuse. This ensures that the connected drives cannot start.
3.1.2. Automatic settings for drive groups and
devices
3.1.3. Drives and devices without automatic
functions
Devices connected via the
“Dimmer” output
(e.g. lighting) have no automatic func-
tions. They can however be operated manually via the display.
Sliding doors
also have no automatic functions. They can also be operated manually
via the display. In addition, sliding doors can be fitted with a close-contact (connection
to a multifunctional input). In this way the control unit knows whether the door is open
or closed.
3.1.4. Automatic awning settings
For connected awnings or awning groups the following automatic settings can be
changed:
•
Light intensity
•
Direction of sun
•
Height of sun
•
Movement position
•
Indoor sensor to be used for the awning
•
Indoor temperature block
•
Outdoor temperature block
•
Frost alarm
•
Wind alarm
•
Rain alarm
•
Enable/Disable automatic reset