ELSEMA 

MD12-2 Metal Loop Detector  

- 5 - 

  

Dip switch 9 and 10 of CH1

 

Frequency

 

Frequency (30 K to 100 KHz). Used to avoid the interference 

Dip switch 9 and 10 

is OFF

 

 

High 

Dip switch 9 is ON

 

 

Medium-High 

Dip switch 10 is ON

 

 

Medium-Low 

Dip switch 9 and 10 

is ON

 

 

Low 

 
Switch 2: Channel 2 Loop Function Selection (7 way dip switch) 
 

Dip switch 1 of CH2 

Function 

Relay Output Type Selection 

Dip switch 1 is OFF

 

 

CH2 relay will be present output

 

Dip switch 1 is ON

 

 

CH2 relay output type is pulse

 

 

Dip switch 2 of CH2 

Function 

Relay Pulse Output Type Selection 

Dip switch 2 is OFF

 

 

When vehicle goes in, CH2 relay is in pulse output for 

200ms

 

Dip switch 2 is ON

 

 

When vehicle has left the loop, CH2 relay will give a 

pulse output for 600ms after a delay of 200ms

 

 
 
 
 
 
 
 
 

Содержание MD12-2

Страница 1: ...change in the inductance of the loop as soon as it detects the metal object in its path The inductive loop which detects the object is made of insulated electrical wire 32 020 32 Strand 2mm diameter...

Страница 2: ...8 being the least sensitive and 0 015 being the most sensitive Dip switch 3 4 and 5 for CH2 sensitivity selection with 0 8 being the least sensitive and 0 015 being the most sensitive Dipswitch Setti...

Страница 3: ...e used to solve the mistake operation recommended Dip switch Settings 3 of CH1 Function Special Functions Dip switch 3 is ON Direction Detection If vehicle is from CH1 to CH2 then CH1 relay should be...

Страница 4: ...elay will give a pulse output for 600ms after a delay of 200ms Dip switch Settings 6 7 and 8 of CH1 Sensitivity Sensitivity Selection Eight Levels Choices Dip switch 6 7 and 8 is ON 0 015 highest sens...

Страница 5: ...nel 2 Loop Function Selection 7 way dip switch Dip switch 1 of CH2 Function Relay Output Type Selection Dip switch 1 is OFF CH2 relay will be present output Dip switch 1 is ON CH2 relay output type is...

Страница 6: ...Selection Dip switch 3 4 and 5 is ON 0 015 highest sensitivity range Dip switch 3 and 4 is ON 0 02 Dip switch 3 and 5 is ON 0 04 Dip switch 3 is ON 0 08 Dip switch 4 and 5 is ON 0 12 Dip switch 4 is O...

Страница 7: ...tecting Led Continuously On Indicates vehicle detection Blinking slowly Indicates loop is short circuit or the number of twists after the loop is not enough Blinking fast Indicates loop is open circui...

Страница 8: ...have been installed set one detector to high frequency and the other set to low frequency to minimize the effects of cross talk between the two systems The sensing loops and detectors should be positi...

Страница 9: ...etectors Do not install the detector on vibrating objects When the control box is installed within 10 metres of the loop normal wires can be used to connect the control box to the loop More than 10 me...

Отзывы: