iS250/iS250D/iS250Solar SWING GATE OPENER MANUAL
G. EMERGENCY RELEASE
In case of power failure, the unlocking KEY can be used to unlock the operator and the gate
can be moved manually. Turning the key by 90
° will unlock the operator.
H. OPEN MECHANICAL STOPPER
To adjust the open mechanical stopper, follow the steps below:
Step1. Remove the screws from both sides of the motor cover
Step2. Push the front external tube forward separating it from the motor base
Step3. Release the screw on the mechanical stopper to change the position
* The position of the front and rear mechanical stopper indicates the fully Open/Close positions of the gate.
I. ELECTRICAL CONNECTION
After successful motor installation, refer to the user manual of the control card
for automatic operation setup.
7