Application Notes (GLR2708)
Care should be taken with the solid-state outputs that they are protected from inductive loads. This is done by
connecting diodes across your DC inductive load.
Inductive loads such as DC relays must be clamped with a diode across the relay coil. If this is not done the
spikes generated by the DC relay can lock-up the receiver. When a lock-up occurs you will need to remove the