(1) TEST MODE

Turn the LUX  control and the TIME control
counter clockwise to the edge –  the TEST
position.

Turn on the wall switch. The light starts warm-up
for 1 minute. During 1 minute warm-up period, the
light will stay on.

Walk through the detection area.    The light turns
on when you move and turns off when you stop.

For a smaller coverage area, point the sensor
down; for a larger coverage area, point the sensor
up.

(2) TIME ADJUSTMENT

The TIME adjustment controls how long the light will 
stay on after the motion has been detected. 

About 5 seconds

About 12 minutes 

(3) LUX ADJUSTMENT

The LUX adjustment determines at what light level the 
lighting system will start operating when you set the 
sensor to automatic operation. 

(4) AUTOMATIC OPERATION

Turn on the wall switch.  When the sensor detects 
motion, the light automatically turns on.  The built-in 
photocell turns the sensor off and on according to the 
light level selected by the LUX adjustment. 

(5) MANUAL OVERRIDE CLICK TWICE

Automatic switching can be overridden to allow the 

lighting to illuminate regardless of movement or light 

sensitivity. Turn the switch OFF - ON - OFF - ON 

within 2 seconds. 

In manual override mode, the lighting will remain on 

for approx. 4 to 6 hours regardless of movement. Then 

the motion switch will return to automatic mode.

You can also manually set the motion switch to 

automatic mode by turning it off for 10 seconds, and 

then on again.

TROUBLESHOOTING

Light does not turn on: 

Confirm that you have made a correct “wiring 
connection”.

Check if you have already turned on the 
connected wall switch, or circuit breaker.

Examine if the bulb of the lighting system is in 
good condition or loose.

Adjust the LUX control knob by turning it counter
clockwise.

Light remains on: 

Make sure the wiring connection is correct.

SPECIFICATIONS

 

Power Requirement 

AC 220 ~ 240V / 50Hz 

Lighting Load 

Up to 1000W Halogen/ 
Incandescent 
Up to 400W Fluorescent 
Up to 150W LED 

Detection Field 
(at 20

°

C)

Up to 200° and 12 meter 

Swiveling Angle 

Vertical 35° Horizontal 70° 

Mounting Height 

1.8 ~ 2.0m Wall Mount   
or 2.5 ~ 4.0m Ceiling Mount 

Sensor Operation 

Auto/Manual Override 

Time Adjustment 

Approx. 5 sec ~ 12 min 

Lux Adjustment 

Approx. 30 ~ 200 Lux 

Warm Up Time 

About 1 min. 

Protection Class 

II 

Protection Degree 

IP44 

Safety 

CE 