ELRO AS80MA11 Скачать руководство пользователя страница 3

 

Testing 

 

(1)  Go to System, and select ARM 

 

 

 

 

(2)  Wait for 30 secs, then separate the detector from the magnet (at least 3.5cm 

distance apart). 

 

(3)  If the test is successful the system will trigger an alarm (alarms are listed in 

“Events”). 

 

Notes

: It is necessary that the system is powered and connected to internet. 

 

(4)  If the test is unsuccessful, please check the troubleshooting section. 

 

Mounting 

1. Mount the Magnetic Detector in dry interior locations only. 

 

2.  Do not place the unit near combustible substances or any source of heat, e.g. 
fires, radiators, boilers etc. 

 

Note: 

Mounting the detector to a metal frame or within 1 meter of metalwork (e.g. 

radiators, water pipes) may affect radio range of the device. Please use plastic or 
wooden spacers to separate the detector and metal surface when required. 

Installation 

 

1.  Fit the magnet on the moving part of the door / window opposite the detector (or 

vice versa, if necessary). Use the provided self-adhesive tape to secure them in 
place. 

 
 
 
 
 
 
 
 
 
 
 
 

2.  Make sure the parallel gap between the magnet and detector is less than 20mm 

and that they are aligned. An alarm will be triggered if the gap is greater than 
35mm. 

3.  Perform the test using the same steps described in Operation & Testing section 

above to ensure the unit is working properly. 

Maintenance 

1.  Low Battery: When the battery becomes low, the detector will report back to the 

gateway every 20 minutes. If the door or window is open the LED will flash to 
indicate low battery condition to the user. 

2.  If the battery needs to be changed, please insert the batteries at a 45° angle as 

shown below. 

Содержание AS80MA11

Страница 1: ...agnet Battery Screw mounting hole Battery Mylar for models with battery included 5 The following screen will appear This means the gateway is entering binding mode Binding with Homesys 1 Models with battery included The battery is isolated by a mylar film to deactivate the detector during shipment Do not remove the mylar film yet Models without battery included Do not insert the battery yet 2 Log ...

Страница 2: ... the detector 2 Repeat steps 4 to 5 of the Binding with ELRO Smart Home Alarm section 3 Locate the Tamper switch as shown below Tamper switch 4 Press and hold the Tamper switch for about 4 seconds and release The LED will start to blink repeatedly This implies detector has now entered the binding mode and is waiting to receive binding signals from the gateway 5 Within 5 seconds the LED indicator w...

Страница 3: ...e device Please use plastic or wooden spacers to separate the detector and metal surface when required Installation 1 Fit the magnet on the moving part of the door window opposite the detector or vice versa if necessary Use the provided self adhesive tape to secure them in place 2 Make sure the parallel gap between the magnet and detector is less than 20mm and that they are aligned An alarm will b...

Страница 4: ...until the LED flashes moderately Release the button The unit enters code binding mode and a 30 second countdown starts 2 Within the 30 second countdown press and hold the link button for more than 6 seconds until the LED turns off 3 Remove the batteries and re insert them again If the LED blinks slowly for 30 seconds this implies the device is reset back to factory mode Specifications Battery CR24...

Отзывы: