background image

15.09.2008 

 

PULSAR 2  

v 2.15

 

 
 
 

 
 

 

 

 

 
 

 

PULSAR 2

 is a fast, microcontroller-based charger suitable for use with various types of batteries. Special design of 

hardware and software makes it possible to charge batteries with high currents without risk of damage and in some 
cases even improving their durability. During charging process all important parameters are displayed on LCD and 
transmitted via serial port (RS232) to a desktop computer. Additional software allows visualization of changes in 
voltage, current, voltage time derivative and temperature during whole charging process which allows user to 
determine precisely status of batteries and decide whether they need conditioning or not. A data communication 
between 

Pulsar 2

 and 

Pulsar-EQUAL

 Equalizer (Balancer) is possible and increases the safety of working with Li-Xx 

packs. 
 
 

 

Technical specification 

Battery types supported 

Ni-Cd, Ni-MH, Pb-bat, RAM, Li-Ion, Li-Pol, Li-Ta, Li-Ph 

(Li-Ion FePO4)

 

Supply voltage 

10 – 16V DC (car battery min 30Ah (70Ah recommended)  or power supply 
14V/30A) 

Low voltage alarm level (alarm) 

min 10 – 11,5V adjustable in 

Setup

 

max 16V 

Charging voltage 

0.5 - 60V from 1 up to 32 Ni-Cd cells 

Charging current 

200mA – 9,9A (250W) 

Discharging current 

200mA – 9,9A (250W) with energy return 
200mA – 9,9A (35W) with heat dissipation 

Temperature measurement 

0 - 99

°

C with 0.1

°

C accuracy 

Voltage measurement 

0,1 – 60V  

Current measurement 

0,1 – 11A  

Time measurement 

up to 14 hours 

Max voltage on supply battery 

Revers

  -  On 15,3V 

Содержание PULSAR 2

Страница 1: ...ies and decide whether they need conditioning or not A data communication between Pulsar 2 and Pulsar EQUAL Equalizer Balancer is possible and increases the safety of working with Li Xx packs Technica...

Страница 2: ...th E key Adjusted parameter is blinking on LCD panel Tmax on Start analyzing temperature Ton and Toff Ton if packet temperature exceeds set up Ton temperature process will start only after cell temper...

Страница 3: ...is a possibility to set up different value of charging discharging current Work mode discharging Disch charging Charge discharging charging Dis Ch charging discharging Ch Dis Cell Type Ni Cd Ni MH Pb...

Страница 4: ...arging 8 cells 8 0A actual measured current 7 2V actual measured voltage marker of decreasing voltage E marker of current limit blinking 00 12 34 time elapsed from start of the process 1 915Ah energy...

Страница 5: ...ing voltage i marker of inflex point detection blinking S marker of slow start mode blinking 00 16 00 time elapsed from start of the process 2 326Ah energy taken Vb 12 1V supply voltage 40 0 C battery...

Страница 6: ...nking S marker of the slow start mode blinking 01 23 25 time elapsed from start of the process 1 298Ah energy taken Vb 12 5V supply voltage 23 7 C battery temperature Charge Keys Function or change pr...

Страница 7: ...cates that charger has limited current due to maximum power F 08 formatting 8 cells 1 8A actual measured charging or discharging current 12 8V actual measured voltage 01 10 04 time elapsed from start...

Страница 8: ...0 0 3 1 2 6 3 V C C marker inform that value is counted for single cell Again pressing E key will repeat the test Battery s internal resistance measurement method is different than method used by cel...

Страница 9: ...ew packets should be done with 0 2 0 3C 3 5 format cycles Regeneration of the packed should be done in 3 5 cycles with 0 2 0 5C Format Regen on Li Ion Li Pol each cell in packets could be parallel to...

Страница 10: ...parison of battery capacity from several processes A column graph allows for quick data comparison i e format or regeneration of packet Red column shows discharging process light red to the first chan...

Страница 11: ...to 30A You must supply PULSAR directly from a car accumulator It is not allowed to supply charger from car lighter socket this can severely damage car wiring system Make sure all cables connecting a b...

Страница 12: ...8 Press E 9 T off in this temperature process will be terminated choose required option using keys in range 50 65 C only if T max is on 10 Press E 11 V off set of minimal supply battery voltage protec...

Страница 13: ...ttery may not be fully charged Caution this function is important when we are charging new or long stored cells Ni Cd and Ni MH Charging 1 Turn on charger battery not connected 2 Press E start 3 Choos...

Страница 14: ...e warm package to fly drive or sail Pulsar 2 is generally set for possible economical use of battery which lead to small increase of temperature during charging So we can increase experimentally charg...

Страница 15: ...ted at time of purchase this is your proof of the date of purchase 2 The guarantee applies only to faults caused by defective components or faulty workmanship on the part of the manufacturer 3 The gua...

Страница 16: ...ge 2 0A rD Delta high Charge 4 0A Frv Fast On Charge 4 0A Frv Reflex On Charge 4 0A Frv V end 4 150V Format 2 2A 2C accu Ni Cd Format 2 2A 2C Regen On Format 2 2A 2C Cycle 2 Test 1 0A accu Ni Cd Dis C...