5.0 REMOTE COMMAND (opz. TZ04/OPT1)
On request it’s possible to fit on the matrix on option cod. TZ04/OPT1 for remote
command by dry contacts (max. 10mt.).
In this caseis available on the rear panel a sub-D 9 p. female connector.
The signals involved are 4 for the inputs and 4 for the outputs and are connected
as follows:
WARNING: Make
connections by dry contacts or O. C. (open collector) devices with the time
relationship as follows:
A
INPUT selection
T1
5 mSec minimum
B
OUTPUT selection
T2
5 mSec minimum
T3
5 mSec minimum
2.0 POWER SUPPLY
The TZ04 must be powered at 230 Vac 50Hz using the cable provided. The cable
must be terminated in the related panel plug on the left at the back of the unit.
The panel plug is complete with fuse-holder for 5X20 fuses.
If the fuse blows, replace with a fuse
with the same rating
as specified on the
back of the unit. (T 500mA).
WARNING
All operations must be carried out by qualified personnel only
who must be informed of the risks of electric shock
In some countries, the power plug must be adapted to local standards. The wires
are identified according to the following coding:
- Brown
PHASE
(Identified with the letter L, may be red)
- Blue
NEUTRAL (Identified with the letter N, may be black)
- Yellow/Green
GROUND
(Identified with the letter E, may be green)
WARNING
A ground connection is mandatory.
The TZ04 can be ordered for powering at 115Vac 60Hz.
The setting is made in factory and cannot be modified by the customer.
ELPRO Video Labs s.r.l.
Strada della Pronda 45/B 10142 - Torino – ITALY
Tel.+39 011 7701583 - FAX +39 011 703751
6
ELPRO Video Labs s.r.l.
Strada della Pronda 45/B 10142 - Torino – ITALY
Tel.+39 011 7701583 - FAX +39 011 703751
TZ 04
4x4 VIDEO AND AUDIO MATRIX
TZ 04
4x4 VIDEO AND AUDIO MATRIX
INPUT sub-D9p.
f.
1
1 – 9
2
2 – 9
3
3 – 9
4
4 – 9
OUTPUT
1
5 – 9
2
6 – 9
3
7 – 9
4
8 – 9
3