ELPRO MDL200 Скачать руководство пользователя страница 1

 

9.0 NOTES 

 
This product is guaranteed for 2 years from the date of purchase. 

 

If the fault in the product is due to improper use or operations 

carried out by third parties, the warranty is forfeited. 

 

During the warranty period, Elpro will repair the faulty units free of charge. 
 
The faulty units must be sent CARRIAGE FREE to the Elpro offices in Turin with a 
regular accompanying note. 
 
The units repaired will be returned CARRIAGE FORWARD to the addressee. 

Outside the warranty period, Elpro will repair the faulty units EX its Turin offices, charging the 
cost of the repair to the customer. 

 

For any problems during installation of the MDL200, 

call the Elpro hot-line 011 9348778 

or E-mail: [email protected] 

 

 

 

MDL200

                                                     

 SWITCHER/HIGH RESOLUTION SCALER 

MDL200

                                              

         SWITCHER/HIGH RESOLUTION SCALER 

 
 
 
 

 

 

 

 

5 inputs with associated audio  

 

Selectable output format 

 

Maintenance of settings 

 

Optional IR remote control 

 

Can be controlled via RS232 

 

MDL200-M 

ELPRO Video Labs s.r.l. 

Via della Praia 4/a FERRIERA di BUTTIGLIERA ALTA (TO) – ITALY 

ELPRO Video Labs s.r.l. 
Via della Praia 4/a FERRIERA di BUTTIGLIERA ALTA (TO) – ITALY 
Tel.+39 0119348778 - FAX +39 0119348779

 

16 

Tel.+39 0119348778 - FAX +39 0119348779

 

Содержание MDL200

Страница 1: ...th associated audio Selectable output format Maintenance of settings Optional IR remote control Can be controlled via RS232 MDL200 M ELPRO Video Labs s r l Via della Praia 4 a FERRIERA di BUTTIGLIERA...

Страница 2: ...ook carefully when installing the MDL200 unit The manufacturer does not assume any responsibility for damages caused by use even correct of its products The data and characteristics of the product may...

Страница 3: ...emote control OPTIONAL The MDL200 transforms a video signal into a high resolution signal Output format is selectable from SVGA to SXGA The Y Cb Cr progressive format from 480 to 1080i is also availab...

Страница 4: ...balanced For details of operation of the IR remote control see chapter 6 0 For the data exchange protocol via RS232 refer to chapter 7 0 7 Th YB Ex Th AC N 7 Th YC Ex Th AC N 7 Th YS Ex Th AC N 7 Th...

Страница 5: ...the risks of electric shock In some countries the plug of the cable must be adapted to local standards The wires will be identified according to the following coding Brown PHASE Identified with the le...

Страница 6: ...DD15p f connectors called PC1 and PC2 Connect the destination Video projector or plasma or TFT monitors to the HIGH RESOLUTION OUT output WARNING If destination is a PLASMA MONITOR could be advisable...

Страница 7: ...level of both audio outputs cannot be regulated Connect the balanced audio output to a set of active speakers or to a stereo amplifier WARNING If the speakers or the amplifier have the input unbalance...

Страница 8: ...e command From this moment on the MDL200 will enable that input at power on The factory setting enables the PC1 input b IR reception IR reception can be disabled maintaining pressed the RESOLUTION SEL...

Страница 9: ...e leds on the console of the MDL200 unit 7th Group 2 keys VOLUME OUT THIS FUNCTION IS NOT AVAILABLE 8th Group 2 keys MICrophone THIS FUNCTION IS NOT AVAILABLE 9th Group 10 keys AUX DRY CONTACTS THIS F...

Страница 10: ...he command has been performed correctly NACK Hex 15 if transmission errors have been detected 7 3 Setting mute audio The host must send the following sequence mX followed by CR where m is the hex char...

Страница 11: ...e the settings made the following characters must be sent on line 53 0D The MDL200 scaler replies ACK Hex 06 if the command has been performed correctly NACK Hex 15 if transmission errors have been de...

Страница 12: ...of the related commands 7 9 Firmware identifier request The host must send the following sequence i followed by CR where i is the hex character 69 The MDL200 scaler replies i hex character 69 R MDL200...

Страница 13: ...NACK Hex 15 if transmission errors have been detected 7 10 3 Setting of color The host must send the following sequence YSXX followed by CR where YS are the pair of hex characters 59 53 XX indicates...

Страница 14: ...ted 7 10 7 Setting of noise reduction filter The host must send the following sequence YNX followed by CR where YN are the pair of hex characters 59 4E X indicates the status of the filter Noise Reduc...

Страница 15: ...nput level 9 dBm Max Frequency response 1 dB from 40Hz to 20KHz Crosstalk 60 dB at 5KHz Distortion 0 03 at 0 dBm with 10K load Hum noise 75 dBm unweighted Outputs Unbalanced 150 with RCA outlet Balanc...

Страница 16: ...ices in Turin with a regular accompanying note The units repaired will be returned CARRIAGE FORWARD to the addressee Outside the warranty period Elpro will repair the faulty units EX its Turin offices...

Отзывы: