Resetting your unit to factory defaults 

You must reset the receiver unit to factory defaults before linking the transmitter and receiver 
units.  

To reset the default factory configuration: 

1.  Press and hold the RSSI push button. 

2.  Power on the 105U-L receiver. 

3.  The 105U-L receiver flashes all LEDs at medium flash (i.e. 1.6 Hz). 

NOTE: If the LEDs do not flash, you must repeat steps 1 and 2 until the LEDs flash before 
continuing. 

4.  Release the RSSI push button within 5 seconds. 

5.  Within a further 60 seconds, press and hold the RSSI push button for 5 seconds (until 

the LEDs stop flashing) and then release. 

6.  The 105U-L receiver lights all LEDs for 2 seconds before returning to normal 

operation. 

NOTE: If the LEDs do not light, you must repeat the process from step 1 until the LEDs 
light before continuing. 

7.  You can now link the transmitter and receiver units. 

Linking your transmitter and receiver units 

You must reset the transmitter unit to factory defaults (to disable encryption) before linking the 
transmitter and receiver units. For more information, see the 105U-L-T Transmitter Quick Start 
Guide

NOTE: You must complete the linking process in 60 seconds. 

To link the transmitter and receiver units: 

1.  Press and hold down the RSSI Pushbutton on the receiver. 

2.  Power on the receiver while holding down the RSSI Pushbutton 

3.  Release the RSSI Pushbutton as soon as the Receiver LEDS flash (within 5 seconds 

of powering the receiver). 

4.  The receiver will flash all LEDs for a maximum 60 seconds while it tries to link to the 

transmitter. 

5.  Power on the transmitter. The transmitter sends a special “Link” message to allow the 

receiver to recognise the transmitter. 

6.  When the units link, the receiver lights all LEDs for 2 seconds before returning to 

normal operation. 

NOTE: If the receiver LEDs continue flashing within the 60 seconds, the units are not 
linked and you should retry the linking process by powering the transmitter off and on 
again. If you exceed the 60 seconds, you must restart the linking process from step 1. 

7.  You can now bench test your configuration before deploying. 

Содержание 105U-L

Страница 1: ...Quick Start Guide ELPRO 105U L Wireless I O Receiver Unit man_905U L R_QuickStart_v1 7 doc...

Страница 2: ...ng a dedicated pair of transmitter and receiver units The basic steps for using your unit are 1 Connect the antenna power supply and transducer signals using the instructions in this document Power su...

Страница 3: ...y with Electrical Safety Standards when connecting SELV AND voltages which are greater than SELV 30VAC or 60VDC together then Relay Output 2 must NOT be used in order to provide sufficient isolation b...

Страница 4: ...is ON D3 Relay Output D3 is ON LEDs with RSSI Push Button Pressed When you press the RSSI push button the unit shows the signal strength by lighting the LEDs from the bottom to the top Signal strengt...

Страница 5: ...ELPRO 105U L Wireless I O Receiver Unit Quick Start Guide ELPRO 105U L Wireless I O Receiver Unit Version 1 7 page 5 of 8 Antenna installation...

Страница 6: ...ter and receiver units You must reset the transmitter unit to factory defaults to disable encryption before linking the transmitter and receiver units For more information see the 105U L T Transmitter...

Страница 7: ...ce with RSS 119 of the Industry Canada rules See the label on the unit for the specific Industry Canada certification number and any other certification designations NOTE Any changes or modifications...

Страница 8: ...n equivalent product if an equivalent product is available This warranty does not extend to Failures caused by the operation of the equipment outside the particular product s specification or Use of t...

Отзывы: