Elpas Personal Safety Bracelet
– User Guide
www.elpas.com
Page 2 of 4
V3/Nov 2014
Regular Band
Initial Activation
The bracelet is shipped from the factory in Sleep Mode to
conserve battery power during shipping.
To activate the bracelet from sleep mode:
Button Press
Orient the tag front-cover side up.
Next press & hold down the call
button for at least 5 seconds.
If the wake-up process is successful the LED Indicator on the
front of the bracelet will illuminate for 3 seconds.
Battery Replacement
Change the bracelet’s status in the host
RTLS application to ‘Inactive’.
Place the bracelet back cover side up.
Then Unscrew the 4 screws and remove the
back cover.
Slide the battery out from under the battery
holder. Dispose of used battery in accordance
with local regulations.
Replace the battery ensuring that the positive
(+) side of the battery faces up.
Close the back cover such that the screw holes are correctly
aligned. Tighten the 4 screws snugly into place. Do not over-tighten
as this may strip the case threads.
Change the bracelet’s status in the host RTLS application back to
‘Active’.
Attaching the Hospital Band Adapters
Place the bracelet back cover side up. Then
Unscrew the 4 screws and remove the back
cover.
Position the bracelet front cover side down.
Next insert the two hospital band adapters
into the grooved slots which are located on
either side of the front cover.
Close the back cover such that the screw
holes are correctly aligned. Tighten the 4 screws snugly into place.
Do not over-tighten as this may strip the case threads
Tamper Band Activation
Touch the two ends of the tamper wrist band together as shown in
the picture below to activate bracelet.
If the wake-up process is successful the LED Indicator on the front
of the bracelet will illuminate for 3 seconds.
Battery Replacement
Change the bracelet status in the host RTLS application to ‘Inactive’.
Place the bracelet back cover side up. Next
unscrew
the
4 screws and remove the back cover.
Slide the battery out from under the battery
holder.
Dispose
of
used
battery
in
accordance with local regulations.
Replace the battery ensuring that the
positive (+) side of the battery faces up.
Close the back cover such that the screw
holes are correctly aligned. Tighten the 4
screws snugly into place. Do not over-
tighten as this may strip the case threads.
Change the bracelet’s status in the host
RTLS application back to ‘Active’.