1
3
6.
Electrical
connection
Follow the installation instructions and the information on the rating plate when connecting the unit.
Comply with all local regulations and standards.
Do not connect the unit to the mains if it has just been transported from a cold environment
into a warm room. Otherwise condensate may develop inside the combi steamer which may
cause damages. Wait for about two hours until the unit has reached room temperature
Electrical connections must be carried out by an approved electrician in accordance with the
regulations of the local electricity supply companies.
6.1
Standard connection
Type 6-23
Connected load
kW
4,8
3,6
5,9
Voltage
V
208 V 3 AC
230V AC
400 V 3N AC
Fuse protection
A
3x15 A
1x16 A
3x16 A
The cross-section of the power cables must be based on the current consumption and on
local regulations.
For USA and Canada the applicable standards: NFPA 70/NEC, CSA C22.2
Next to the appliance an all-pole electric circuit breaker with a contact opening of at least 3mm
has to be provided for on site.
Every unit requires its own connection and fuse protection.
We recommend installation of a residual current circuit breaker with 30 mA.
Model
Joker B
: Upon request the possibility of connection to energy optimising systems is provided for.
Model
Genius compact, Joker T
: The possibility of connection to energy optimising systems is
standard.
Refer always to data given on the type plate.
The appliance must be incorporated into the potential equalisation system (ground).
You find the terminal under the indication plate