A-53
2500S Controller Protocol
The ten-byte binary data format displayed in hex by COMDUMP for correct
operation with Elo driver software is as follows:
A-4002 Controller Protocol
If the controller is jumpered for A-4002 emulation mode, the output will be the
six-byte binary format as follows:
In this mode, the first four bytes in each packet will be decreasing, followed by
a zero byte, and a byte from 00 to 0F (hex). The Z value (byte 6) will be 00
when you lift your finger.
Byte
Description
1
ASCII 'U' (55h)
2
ASCII 'T' (54h)
3
Status Byte
4
XLow
5
XHigh
6
YLow
7
YHigh
8
ZLow
9
ZHigh (defaults to 0)
10
Checksum
Byte
MSB
LSB
1
1
1
X11
X10
X9
X8
X7
X6
2
1
0
X5
X4
X3
X2
X1
X0
3
0
1
Y11
Y10
Y9
Y8
Y7
Y6
4
0
0
Y5
Y4
Y3
Y2
Y1
Y0
5
0
0
0
0
0
0
0
0
0
6
0
0
0
0
Z3
Z2
Z1
Z0