background image

ELOE00XZKE001 

 

3.3 

Power Supply Connection 

The  converter  contains  two  isolated  parts  that  have  to  be  supplied  from  two 

supplies isolated from each other. The RS-232 interface circuit is supplied from the 

TE signals. The TE has to supply at least one of TxD, RTS and DTR signals. The 

power take-off does not exceed c.3mA. 

The current loop circuits need the power supply as described in 3.2 chapter. If the 

converter  operates  in  the  passive transmitter and receiver mode it works with the 

current  supplied via the opposite converter and does not need the external power 

supply.  When in the active receiver or transmitter mode, the power supply to the 

loops  is  needed.  The  supply  is  connected  via  the  DC  connector  on  the  converter 

case or via 8 (positive) or 4 (negative) contacts on the current loop connector.  

The power supply of 12V/100mA is used most often, E0Q4 type. The power supply 

voltage may be of maximum 24V for one supplied current loop thus up to 50mA. 

 

4.0 

Specifications 

4.1 

Parameters 

  RS-232 interface 

DCE 

  RS-232 connector 

DB9F 

  Current loop interface 

transmitter and receiver 

 

active / passive 

  Current loop connector 

DB9M 

  Loop current in idle mode 

20mA 

  Isolation between interfaces 

1 kV 

  Transmitted signals 

TxD and RxD, full duplex 

  Control signals 

are not transmitted, local jumpers 

 

RTS-CTS, DTR-DSR-DCD 

  RS-232 connector 

DB9F, DCE 

  Transmission mode 

half-duplex 

 

Power supply 

external DC supply 6V/200mA 

  Maximum range of the link with 

 

parameters: 200Ohm, 50nF / 1km 

1000m 

  Maximum data rate 

115 200 bps 

  Minimum data rate 

50 bps 

  Supply 

typ. 12 V, max. 24 V / 50 mA 

  Dimension: Width x Length x Height 

34 x  64 x 17 mm 

  Weight 

25 g 

Содержание ELO E00X

Страница 1: ...RS 232 Miniature Converter to Current Loop ELO E00X Operation manual ...

Страница 2: ...Operation principles 3 3 0 Installation 3 3 1 RS 232 interface connection 3 3 2 Two Modems interconnection 4 3 3 Power Supply Connection 5 4 0 Specifications 5 4 1 Parameters 5 4 2 Other 6 5 0 Testing 6 5 1 Auto test 6 6 0 Troubleshooting 7 7 0 Ordering Information 7 ...

Страница 3: ...nables to span the metallic link of the resistance up to 500 Ohm using the power supply of 12 V 2 0 Operation principles E00X converts TxD signal into the transmitting cable pair of the current loop and the signal from the receiving pair into the RxD thus the full duplex connection is carried out In the idle mode the 20mA current flows through each current loop The maximum transmission rate is 115...

Страница 4: ...ach loop the twisted pair should be applied to limit the radiation and particularly the disturbance from outside Each loop connects one transmitter to one receiver and has to contain a power supply The transmitter or receiver supplies this power most often it is so called active transmitter or receiver whereas the passive receiver is a consumer and the passive transmitter is a current switch that ...

Страница 5: ...r on the converter case or via 8 positive or 4 negative contacts on the current loop connector The power supply of 12V 100mA is used most often E0Q4 type The power supply voltage may be of maximum 24V for one supplied current loop thus up to 50mA 4 0 Specifications 4 1 Parameters RS 232 interface DCE RS 232 connector DB9F Current loop interface transmitter and receiver active passive Current loop ...

Страница 6: ...s 5 0 Testing If interconnected properly both diodes light up on each modem Any simple communication test can be used terminal emulator 5 1 Auto test You can test either single converter or connected to the terminal equipment with the external supply of 12 24 V The DB9M connector contacts are interconnected via two jumpers 7 2 and 9 1 Both diodes must be alight The transmitted sign has to appear i...

Страница 7: ...k if both diodes light after installation Check the power supply Check RS 232 connection Connection in normal Check the power supply operation quit working Check the cable connection Use auto test and find out if the converter is OK 7 0 Ordering Information Supply code is ELO E00X ...