background image

 

 

AUTO-SCANNING WITH DIGITAL CONTROL 
LCD COLOR MEDICAL MONITOR

 

 

AMM15TK2/AMM15TK2-TE/AMM15TK2-TEW 

 

Operation Manual 

 

 
 

For future reference, record the serial 
number of your display monitor in the 
space below: 
SERIAL number  
The serial number is located on the 
back of the monitor 

Содержание ADVAN AMM15TK2

Страница 1: ... LCD COLOR MEDICAL MONITOR AMM15TK2 AMM15TK2 TE AMM15TK2 TEW Operation Manual For future reference record the serial number of your display monitor in the space below SERIAL number The serial number is located on the back of the monitor ...

Страница 2: ...of items that are of importance in terms of installation operation or maintenance of the Equipment although the failure does not inflict the bodily harm to the patients ADAVN INT L CORP 2005 ELO is a Registered trademark of Elo TouchSystems Inc All other trademarks are the property of their reference owners This document is subject to change without notice Advan provides this information as refere...

Страница 3: ...tions 11 Prepare for Unpack 11 12 DDC 13 Installation 13 Screen Position Adjustment 14 Connecting the Power Cord 14 Power Management Function 15 Power Management System 15 User Controls 16 Standard OSD Operation 16 OSD Function Description Analog 17 OSD Function Description C or S Video 18 Specification Of AMM15TK2 19 Supported Modes 20 Connectors 21 Troubleshooting 22 Electromagnetic Compatibilit...

Страница 4: ...evant operating room complies with the applicable IEC and CE requirements Warning Federal law United States of America restricts this device to use by or on order of a physician The ADVAN Int l Corp AMM15TK2 Series Monitor has been tested under UL 60601 1 standard and UL listed for Medical application 4 ADAVN Int l Corp reserves the right to make improvements in the product s described herein Prod...

Страница 5: ...r connecting the camera 12 Do not place the monitor or any other heavy object on the power cord Damage to the cable can cause fire or electric shock 13 Monitor with power supply is suitable for use in patient environment 14 DO NOT stack more than 8 boxes high This equipment has been tested and found to comply with the limits for medical devices in IEC 601 1 2 2003 These limits are designed to prov...

Страница 6: ...signed for operation in a horizontal position Never operate the unit in a vertical position 15 Keep the unit away from equipment with strong magnets i e a large loudspeaker 16 Do not expose the monitor to moisture or excessive dust 17 Equipment with SIP SOP connectors should either comply with IEC 60601 1 and or IEC 60601 1 1 harmonized national standard or the combination should be evaluated Do n...

Страница 7: ...ir technology to improve flat panel environment utilizing numerous ergonomic mounting solutions to allow creative use in conjunction to product application The monitor is able to properly function even in case of upgrade video cards or software because of the wide auto scanning compatibility range without requiring to buy a new monitor The internal microprocessor digitally controls auto scanning F...

Страница 8: ...ase and Power on off Auto adjust exit OSD menu Auto Button Adjust brightness contrast directly with the adjustment increase decrease buttons Indicators On Screen Display OSD function Power LED indicator is lit when the monitor is on and blinking when the monitor is power save standby mode Display formats VGA SVGA and XGA VESA DDC1 and DDC2B Plug and Play Functions 8 ...

Страница 9: ... for like equipment This is typically warm water and mild detergent for all surfaces or 70 IPA for the touchscreen surface Possible chemicals include 70 isopropyl alcohol 6 aqueous ammonia Cidex 2 4 glutaraldehyde solution Sodium Hypochlorite bleach 10 Green soap USP 0 5 Chlorhexidine in 70 isopropyl alcohol Ovation Formula 409 Fantastic Wex Cide To clean the screen do not spray liquid cleaners di...

Страница 10: ...ities Tested and certified by UL to UL60601 1 If this mark appears with the indicators C and US the product is certified for both the U S and Canadian markets to the applicable U S and Canadian standards Tested to comply with FCC Class B standards Dangerous high voltage Consult accompanying documents Indicates protective earth ground For indoor use only Direct Current DC power control switch 10 ...

Страница 11: ...our monitor prepare a suitable workspace You need a stable and level surface near a grounded wall outlet in an area which is relatively free of glare from sunlight or other sources of bright light The monitor is cooled by natu convection it has no fan ral For optimum performance do not block the cooling vents While unpacking the monitor inspect it and other package contents for shipping damage tha...

Страница 12: ...ou will need to ship or transport the monitor in future AMM15TK2 Series Medical Monitor VGA cable S Video cable BNC cable and BNC to RCA adapter AC power cord and AC Adapter CAUTION Manufacturer Ault Inc Model No MW160KA1203F54 User Manual Touch screen DB9 data cable and floppy disk touchscreen driver optional 12 ...

Страница 13: ...oller card 2 Use the S Video cable that provides S Video connector and connector to the S Video port on the video source device ex VCR Camera system 3 Use the BNC cable with the BNC to RAC adapter that provides composite video connector and connector to the composite video port on the video source device 4 Use the RS 232 serial cable that provides DB9 pin connector and connect to the 9 pin connect...

Страница 14: ...rea This monitor has an universal AC adapter that allows operation in either AC 100 240 Vac voltage area No user adjustment is required Plug one end of the power cord to the AC adapter plug another end to a proper AC outlet The cord set should have the appropriate safety approvals for the country in which the equipment will be installed and marked HAR For 120 volt Applications use only UL Listed d...

Страница 15: ...e vertical sync signal is restored Off Mode The monitor goes into power off mode when the vertical and horizontal sync signals are off for about 10 seconds In this mode the screen goes off and the power LED blinks for 1 seconds On and 1 second Off The screen is displayed after the vertical and horizontal sync signals are restored Power Management System The AMM15TK2 Series Medical Monitor complies...

Страница 16: ...ated To move downward in the OSD menu 5 Menu To enter OSD 6 Select Enter a sub menu or select a menu item If video display option is adopted switch PC display to Video display and vice versa by one touch when OSD menu is not activated 7 Auto Button One touch Auto adjust or Exit OSD menu Standard OSD Operation 1 Press Menu button to activate the OSD 2 Use then keys to move through the menu The para...

Страница 17: ...m3 System4 for color temp Red Balance Red Green Balance Green Blue Balance Blue DPMS Enable or Disable DPMS Auto Source Select Enable or disable auto source selection Freeze Frame Enable or disable freeze frame Zoom Enable zoom in function Scale Mode Choose scale mode between Fill Screen Aspect Ratio One to One Input Source Select Choose input source between Analog RGB Composite Video Super Video ...

Страница 18: ...ownward OSD Background Choose between Opaque and Translucent User Timeout Set OSD screen appearing time Color Temp Choose between Default System1 Sytem2 Sytem3 System4 for color temp Red Balance Red Green Balance Green Blue Balance Blue DPMS Enable or Disable DPMS Auto Source Select Enable or disable auto source selection Freeze Frame Enable or disable freeze frame Zoom Enable zoom in function Vid...

Страница 19: ...o Signal Input Connector Touchscreen RS 232 DB 9 Optional Operating Temperature Humidity 50 F 104 F 10 C 40 C 30 75 Without Condensation Storage Temperature 4 F 140 F 20 C 60 C Storage Humidity 10 90 Max Without condensation Environment Atmospheric Pressure Within 500 to 1060 hPa Display Monitor DC 12 V 3 5 A Power Source AC Adapter AC 100 240 V Regulations Safety and EMC UL 60601 1 EN60601 1 EN60...

Страница 20: ... 31 5 70 4 720 400 31 5 70 6 640 480 31 5 60 7 640 480 35 0 67 8 640 480 37 9 72 9 640 480 37 5 75 11 800 600 35 1 56 12 800 600 37 9 60 13 800 600 48 1 72 14 800 600 46 9 75 16 832 624 49 7 75 17 1024 768 48 8 60 18 1024 768 48 4 60 19 1024 768 56 5 70 20 1024 768 60 75 ...

Страница 21: ...HSB 15 FRF7 LEOCO or equivalent Description Pin Pin Description Red Video 1 9 NC Green Video 2 10 VGA CON Blue Video 3 11 NC NC 4 12 SDA DDC1 2 Logic Ground 5 13 H sync Red Video Ground 6 14 V sync Green Video Ground 7 15 SCL DDC2B Blue Video Ground 8 Touch Port 9Pin D subminiature connector Description Pin Pin Description DCD 1 6 DSR RXD 2 7 RTS TXD 3 8 CTS DTR 4 9 RINC Logic Ground 5 ...

Страница 22: ... specification of graphics adapter and monitor is in compliance which may be causing the input signal frequency mismatch Using Auto adjust button if still display abnormal picture then adjust Frequency Clock Phase H Position and V Position with non standard signals Using OSD in case of missing full screen image please select other resolution in your Operating System Windows 95 98 NT or other verti...

Страница 23: ... operation Continuous This monitor has been tested to comply with IEC EC 60601 1 and IEC EN60601 1 2 Certified by UL to medical standard UL60601 1 UL cUL Mark Because many medical offices are located in residential areas this monitor in addition to the medical requirements has also been tested and found to comply with the limits for FCC Class B computing devices in a typically configured system It...

Страница 24: ...24 ...

Страница 25: ...25 25 ...

Страница 26: ...26 26 ...

Страница 27: ...27 27 ...

Страница 28: ...authorization Buyer will be responsible for packaging and shipping the defective goods to the Advan Service Facility with shipping charges prepaid Limitation of Warranty Monitor For 18 months after the date of purchase ADVAN or its Authorized Service Centers will repair or replace if defective in material or workmanship This Limited Warranty does not include cle aning or damage caused by accident ...

Страница 29: ...stallation of Advan s product s by Advan any authorized dealer or any other person Technical Assistance For technical assistance please call 510 490 1005 between 8 00 a m and 5 00 p m PST Monday through Friday or email to support mail advancorp com with a description of your technical issues Service If your Medical Monitor needs service call Advan Customer Service at 510 490 1005 between 7 00 a m ...

Страница 30: ...panel molded to the precise shape of a display s face A scratch resistant hard coated plastic cover sheet may be clear for best image clarity or have an antiglare finish The IntelliTouch Controller The IntelliTouch controllers provide the drive signal for touchscreen convert the received analogue signals into digital touch coordinates and send these coordinates to the computer Touchmonitor install...

Страница 31: ... will appear You will need to select serial port type of touchscreen controller and language 8 Complete the setup program 9 Shutdown and restart windows NT 10 Click the start button then click control panel 11 Double click touchscreen control panel 12 Click the calibrate button and touch each of the three targets as they appear on the screen Contacting ELO www elotouch com ELO Touchsystems INC 650...

Страница 32: ...32 ADVAN INTERNATIONAL CORPORATION 47456 Fremont Blvd Fremont CA 94538 Tel 510 490 1005 Fax 510 490 1151 Web Page http www advancorp com ...

Отзывы: