3. OPERATING THE WATER HEATER 

 

Connect the water heater to the electrical socket. The heating indicator will be lit as long as the heating element is energized. 
The light will go out when the desired temperature is reached. 

The setting of the water temperature can be modified by turning the Temperature Controlling Knob up to 75ºC max. 

The thermostat will maintain the water temperature as long as the water heater is connected to the electricity supply. 

If there is any risk of frost conditions may be opportune to empty the water heater. It could be done by means of the 
Pressure Relief Valve. 

 

Should any continuous water steam or boiling water is delivered at draining hole or at any hot water system tap, disconnect 
immediately the water heater from the electrical socket and get in contact with after sales service. 

 

4. MAINTENANCE 

IMPORTANT: Check every month that the Pressure Relief Valve is not blocked. Operate the spanner to drainage position. If 
the Pressure Relief valve is obstructed it must be replaced. 

Every two years it is necessary to arrange heating element de-scaling works at the same time it is necessary to check the 
magnesium anode if required. The warranty will not cover any damage caused by the inobservance of this point and if the 
anode is completely gone due to lack of maintenance. 

Clean and dust with a dry, soft cloth only when the unit is disconnected and cold.  

Do not use solvents or abrasive products for cleaning. Do not immerse the electric water heater in water. 

This thermal radiator has been manufactured under an assured quality system using environment friendly processes. Please 
take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right way. 

 

 

0.8MPa

Fixed Screw Nail

Pressure relief

Water- drainage Spanner

Water-drainage Position

0.8MPa

Cold Water Inlet

Hot Water Outlet

Temperature
Controlling

Knob

Heating Indicator

Plastic Cover

Содержание GTS-15

Страница 1: ...INSTALLATION INSTRUCTIONS AND USER GUIDE GTS 10 GTS 15 Please read these instructions CAREFULLY before installing or using this appliance for the first time ELECTRIC STORAGE WATER HEATER GTS ...

Страница 2: ...he guarantee will not cover damage caused if dielectric hoses are not fitted The use of this water heater is forbidden in areas where gases explosive or inflammable substances are present Ensure the power supply to the socket into which the appliance is plugged is in accordance with the rating label on the heater This appliance must be earthed Keep the power cable away from the hot body of the ele...

Страница 3: ...ance This water heater is to be installed exclusively in vertical position Inlet and outlet must be always in the lower part of the water heater Water connections All the fittings are G1 2 Before making the water connections it is necessary to clean all the pipes to prevent that any debris is introduced in the water heater ATTENTION Never connect directly inlet and outlet to the existing pipes Die...

Страница 4: ...to the socket into which the appliance is plugged is in accordance with the rating label on the heater This appliance must be earthed All models are supplied with an electrical interrupt cut out This will switch off the heater if for any reason it overheats Should the cut out operate disconnect the water heater from the electricity supply and remove the cause for the overheating Commissioning IMPO...

Страница 5: ...hat the Pressure Relief Valve is not blocked Operate the spanner to drainage position If the Pressure Relief valve is obstructed it must be replaced Every two years it is necessary to arrange heating element de scaling works at the same time it is necessary to check the magnesium anode if required The warranty will not cover any damage caused by the inobservance of this point and if the anode is c...

Страница 6: ... this pro man health w n about recyc hop where you Th Li Brown Blue Yellow Green 10 tion kWh elec kWh ging indicates he applicable oduct is dispos which could o cling of this pr u purchased t hermal imiter Tem Con No cha GTS10 10 L 1500W 230V 6 5A 0 8MPa 75ºC IPX4 Vertical 0 50 kWh 24 6 3kg XXS C 29 02 636 15 0 10 3 13 that this prod collection poi sed of correct therwise be c roduct please he pro...

Страница 7: ...ur es www elnur global com www elnur co uk Como parte de la política de mejora continua Elnur s a se reserva el derecho a realizar modificaciones técnicas sin previo aviso As a part of the policy of continuous product improvement Elnur s a reserves the right to alter specifications without notice 90890514 R4 ...

Отзывы: