3. OPERATING THE WATER HEATER
Connect the water heater to the electrical socket. The heating indicator will be lit as long as the heating element is energized.
The light will go out when the desired temperature is reached.
The setting of the water temperature can be modified by turning the Temperature Controlling Knob up to 75ºC max.
The thermostat will maintain the water temperature as long as the water heater is connected to the electricity supply.
If there is any risk of frost conditions may be opportune to empty the water heater. It could be done by means of the
Pressure Relief Valve.
Should any continuous water steam or boiling water is delivered at draining hole or at any hot water system tap, disconnect
immediately the water heater from the electrical socket and get in contact with after sales service.
4. MAINTENANCE
IMPORTANT: Check every month that the Pressure Relief Valve is not blocked. Operate the spanner to drainage position. If
the Pressure Relief valve is obstructed it must be replaced.
Every two years it is necessary to arrange heating element de-scaling works at the same time it is necessary to check the
magnesium anode if required. The warranty will not cover any damage caused by the inobservance of this point and if the
anode is completely gone due to lack of maintenance.
Clean and dust with a dry, soft cloth only when the unit is disconnected and cold.
Do not use solvents or abrasive products for cleaning. Do not immerse the electric water heater in water.
This thermal radiator has been manufactured under an assured quality system using environment friendly processes. Please
take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right way.
0.8MPa
Fixed Screw Nail
Pressure relief
Water- drainage Spanner
Water-drainage Position
0.8MPa
Cold Water Inlet
Hot Water Outlet
Temperature
Controlling
Knob
Heating Indicator
Plastic Cover