The product must be installed with the power cord side downwards with at least 5º, it must not be installed in 
a horizontal position or upwards. 

 

 
 
 
 
 
Initial Use: 

The unit may emit odour or vapour on initial use or if the heater has not been used for an 

extended period. 

Warning

: Remove the rubber lamp protectors before using the appliance for the first time. 

 
3.- OPERATION 
 
REMOTE CONTROLLER OPERATION 

Infrared IFC-2000 is operated using the remote control supplied with the heater. Insert 2 x AAA Alkaline 
batteries into the remote control.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
Inserting Batteries 

Insert 2 AAA/ Alkaline type batteries into your remote control 
1.

 

Flip the backside of your remote control and pull out battery cover. Insert the batteries in accordance with 
the instructions and polarity of the batteries. 

2.

 

Change the batteries in the same way described above. 

 

Warning: 

1.

 

Replace the old batteries with the same type batteries. Otherwise, your heater may not function well. 

2.

 

Pull out the batteries in case of long terms of disuse to prevent leakage which may impair your remote 
control. 

3.

 

Do not allow water or liquid to get into the remote control.

 

Timer Adjustment 

Press Timer button (5) and use the Up and Down buttons (2) and (3) to select the number of hours the heater 
will be working. The heater will be working providing the selected heat level during these hours. When the time 
has finished, the heater will automatically disconnect the heating elements. 

 

 

Remote Control Function 

Button 

Function (Heater On)  Function (Heater Off)  LED Display on 

Heater 

Turns heater on or off 

 

 

Increase Heat Level or 

Timer hours 

Turns heater on to 
Level 4 (maximum) 

L4 

Decrease Heat Level or 

Timer Hours 

Turns heater on to 

Level 1 (minimum) 

L1 

Enable Heat Level 

adjustment 

 

L [n] 

Enable Timer adjustment 

 

[0H]-[24H] 

Содержание Gabarron IFC-2000

Страница 1: ...INFRARROJO DE CARBONO CARBON INFRARED HEATER WALL CEILING MOUNTING MONTAJE MURAL O TECHO IFC 2000 Lea estas instrucciones atentamente antes de instalar o utilizar el aparato por primera vez Please read these instructions CAREFULLY before installing or using this appliance for the first time ...

Страница 2: ...ther the connecting cable nor any other object must come into contact with the heater This heater should be switched off at the isolating switch before any repair work is carried out The installation must be carried out in accordance with the current electrical regulations The heater should not be installed just below an electrical socket outlet or dripping clothes The heater is to be installed so...

Страница 3: ...e components of the heater or replace the components with the ones that do not meet the safety requirements WARNING The surface of this heater can be hot Parts of the heater may exceed 200ºC CAUTION Some parts of this product can become very hot and cause burns Particular attention must be given when children and vulnerable people are present WARNING IN ORDER TO AVOID OVERHEATING DO NOT COVER THE ...

Страница 4: ...bellow than 1 8m from the floor Consideration should be given to any temporary or occasional additions such as stages or platforms and adjusted accordingly For outdoor use or other areas with air movement wind the directional infrared spread may reduce by 1 3 to 1 2 Wall ceiling installation swivel brackets are provided with the heater which has been specifically designed to allow this product to ...

Страница 5: ...hange the batteries in the same way described above Warning 1 Replace the old batteries with the same type batteries Otherwise your heater may not function well 2 Pull out the batteries in case of long terms of disuse to prevent leakage which may impair your remote control 3 Do not allow water or liquid to get into the remote control Timer Adjustment Press Timer button 5 and use the Up and Down bu...

Страница 6: ...t heater cool for 15 minutes and restart heater No heat when L1 2 3 Bulb is damaged ContactTechnical Service o 4 shown on display 6 THECNICAL DATA ERP PRODUCT FICHE Model IFC 2000 Power 2000 W Power Levels 4 levels 2000 1600 1200 800 W Voltage 220 240V Weight 3 kg Dimensions 90 x 13 x 9 cm IP Code IP55 Remote Control Yes 24h Programmable Yes Heating Element Carbon Heating Lamp Information Symbol I...

Страница 7: ...iador No deje cable colgando del extremo de mesas o escalones ni deje que entre en contacto con cualquier superficie caliente No utilice el radiador mientras duerma Nunca deje el radiador desatendido mientras esté en funcionamiento Un manejo inadecuado puede causar heridas graves No utilice alargadores de cable Esto puede causar sobrecalentamiento y causar un incendio No deje ningún objeto encima ...

Страница 8: ...apagar el radiador Nunca desmonte los componentes del radiador ni los reemplace por otros que no cumplan los requisitos de seguridad ADVERTENCIA La superficie de este aparato puede estar caliente Algunas partes del equipo pueden llegar a 200ºC PRECAUCIÓN Algunas partes del aparato pueden estar muy calientes y causar quemaduras Se debe prestar particular atención en presencia de niños y personas vu...

Страница 9: ... ninguna circunstancia instale el IFC 2000 por debajo de 1 8metros sobre el suelo Para uso en exteriores u otras áreas con movimiento de aire la propagación del efecto del infrarrojo puede reducirse de 1 3 a 1 2 Un juego de soportes giratorios para la instalación en la pared techo se suministran con el calefactor Éstos han sido diseñados específicamente para permitir que el producto se instale en ...

Страница 10: ... y polaridad de las mismas 2 Reemplace las baterías siguiendo el mismo procedimiento descrito arriba Advertencias 1 Reemplace las baterías con el mismo tipo De otra manera el equipo no funcionará correctamente 2 Extraiga las baterías en caso de largos periodos de no uso para prevenir posibles pérdidas que pudieran dañar su mando a distancia 3 No permita que agua u otros líquidos penetren en su man...

Страница 11: ... se emite calor con La lámpara puede estar dañada Contacte con el servicio técnico L1 2 3 o 4 en display 6 INFORMACIÓNTÉCNICA FICHA ERP Modelo IFC 2000 Potencia 2000W Niveles de Potencia 4 niveles 2000 1600 1200 800W Tensión de alimentación 220 240V Peso 3 kg Dimensiones 90 x 13 x 9 cm Grado IP IP55 Mando a Distancia Sí Programable 24h Sí Elemento Calefactor Lampara de Carbono Información Símbolo ...

Страница 12: ...herwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product These instructions are only valid in the EU member states El símbolo en el producto o en su embalaje indica que este producto no se puede tratar como de...

Отзывы: