10
BOOST/TIMER LED FUNCTIONING SUMMARY
Blinking red
"Boost" mode active. The heating element is powered for 120 minutes (temperature
of the radiator automatically limited to 65°C).
Blinking Green
"Boost" function active in Timer24 mode. The heating element is powered for 120
minutes (temperature of the radiator automatically limited to 65°C).
Permanent green
"Comfort" function active for 22hrs in Timer24 mode.
Blinking amber
"Boost" function active in Timer12 mode. The heating element is powered for 120
minutes (temperature of the radiator automatically limited to 65°C).
Permanent amber
"Comfort" function active for 10hrs in Timer12 mode.
Key lock function
: It is possible to lock the buttons of the device to avoid inadvertent modifications of the settings.
Press together the [+] and [-] buttons for 3 seconds to lock all the buttons except the [On/Standby] button.
To unlock the buttons press again together the [+] and [-] buttons buttons for 3 seconds. When key lock is activated
the device beeps twice. When key lock is deactivated, the device beeps four times.
NOTE:
In case of interruption of power supply, the system will recover from the previous operative
mode*, with the exception of "Boost" and "Timer" modes.
*The status of the device is saved 5 seconds after a modification occurs.
4. MAINTENANCE
The towel rail doesn't require any type of special maintenance. Clean with a cloth, only when the unit is disconnected
and cold. Do not use solvents or abrasive products when cleaning. The towel rail has been manufactured to assured
quality and according to processes to protect the environment. The towel rail is filled with a precise quantity of special
fluid. Any repairs that may require the opening of the towel rail must only be carried out by the manufacturer. Once
at the end of the useful life of the appliance, take it to a proper waste collection site so that its materials can be
recycled appropriately.
5. ELECTRIC OUTLINE
Voltage:
220
–
240 V~
Input:
300 W / 500 W
IP 44
TECHNICAL SPECIFICATIONS / ESPECIFICACIONES TÉCNICAS
Model / Modelo
TCROM 8 TCROM 12
Power / Potencia (W)
300
500
Voltage / Voltaje (V)
220-240V
220-240V
Frequency / Frecuencia (Hz)
50
50
Length / Anchura (cm)
50
50
Width / Profundidad (cm)
8
8
Height / Altura (cm)
87
128
Weight / Peso(kg)
10
14
Isolation / Aislamiento
Class I
Class I
IP Protection / Grado protección IP
IP44
IP44
F Fuse
T Control thermostat
R Heating element
L Live
N Neutral
EP Earth Protection
(green/yellow)