24
-
CONTROL TYPE: Select the temperature control type. A PID device with default settings programmed is
recommended.
-
OPEN WINDOW DETECTION: Activates when open windows detected (On/Off).
-
INTELLIGENT START-UP: Adaptable start-up activation (On/Off).
-
COMPENSATION: Correction of room temperature (Values from -5ºC to 5ºC).
-
NOMINAL CHARGE: Ecombi Solar can operate with hourly discrimination tariffs of 8 or 14 off-peak hours. Set the
device for 8 or 14 hours according to the number of off-peak hours of your tariff.
3.5.3 Reset and default factory settings
You can reset the unit and restore factory setting configuration.
Default Values
Parameter
8 hours setting
14 hours setting
Sun
: Comfort temperature
21ºC
21ºC
Moon
: Economic temperature
18ºC
18ºC
Frost protection temperature
3ºC
3ºC
UP01
: Initial % of storage charge
100%
100%
UP02
: Starting time off peak period 1
00:00
22:00
UP03
: Ending time off peak period 1
08:00
12:00
UP04
: Starting time off peak period 2
00:00
00:00
UP05
: Ending time off peak period 2
00:00
00:00
UP06
: Charging days of the week
Charging 7 days of the
week.
Charging 7 days of the
week.
UP07:
Ambient sensor Offset
0ºC
0ºC
UP08
: Max. Balancing element
–
working period
5 hours
3 hours
UP09
: Overtemperature protection
2ºC
2ºC
UP10
: Temperature Unit
ºC
ºC
UP11
: Open Window Detection Function
Off
Off
UP12:
Adaptive Start Control
Off
Off
UP13:
Kind of temperature control
PID
PID
UP14
: Weekend Balancing Element restriction
On
N/A
Incorrect time settings, erroneous programming of the reduced rate time and too high temperature settings may result in a high cost
of your electricity bill
.
3.6. Emitter Mode
This operation mode is used when it is necessary to heat the room temporarily and there is no need for storage heating. To set
this mode, turn off the unit by pressing the main switch on the back-side panel and keep pressed
at the same time you turn
on the unit by pressing the main switch until the message 19.0E is displayed on the display.
-
Emitter mode is a temporary operation mode. You cannot access from this mode to general setting menu,
operation mode menu or any other settings.
-
Use
and
to modify the set-point temperature for this operation mode. The unit will turn on the
balancing heating element if required in order to provide instantaneus heat to the room.
-
The unit will not charge within this mode.
To exit emitter mode and go back to the commom operation mode, just turn off and turn on the unit again by pressing the main
switch on the back-side panel.