Продукт Elnec BeeHive8S - это высокотехнологичное устройство для программирования микросхем. Пользовательский мануал можно загрузить бесплатно с нашего сайта. Узнайте все возможности и функционал этого продукта, скачав мануал с manualshive.com.
User's Manual for
BeeHive8S
Fast universal 8x 48-pindrive Stand-Alone concurrent multiprogramming system
ELNEC s.r.o.
Presov, Slovakia
March 2009
Страница 1: ...User s Manual for BeeHive8S Fast universal 8x 48 pindrive Stand Alone concurrent multiprogramming system ELNEC s r o Presov Slovakia March 2009...
Страница 2: ...form on any medium for any purpose Information provided in this manual is intended to be accurate at the moment of release but we continuously improve all our products Please consult manual on www eln...
Страница 3: ...WEB site www elnec com if current one will be out of date Conventions used in the manual References to the control program functions are in bold e g Load File Device etc References to control keys ar...
Страница 4: ...ed in the socket properly independently of the status of other programming modules This results in seven programming modules working while you replace the programmed chip in the eighth Graphical contr...
Страница 5: ...ntact check poor contact pin to socket before it programs each device These capabilities supported by overcurrent protection and signature byte check help prevent chip damage due to operator error Bee...
Страница 6: ...site Free software updates are available from our Internet address www elnec com Online technical support is available within promised 24 hours time limit or you may call us during business hours fro...
Страница 7: ...power sleep LED of site 4 YES Button 5 ISP connector 6 graphical control unit with touch screen 7 fan s grid 8 temperature controlled fans 9 banana jack for connection to ground 10 banana jack for ESD...
Страница 8: ...ption of the control program turn off programmer but the content of programmed cells may remains undefined Don t unplug the target device from the ZIF socket during work with device BUSY LED on Optimi...
Страница 9: ...use other ISP cable other material length programming may become unreliable BeeHive8S can supply power to the programmed device pin 1 of ISP connector and the target system pin 19 and 20 of ISP connec...
Страница 10: ...t orientation of Diagnostic POD for ISP connectors 2 Interconnect the 20 pins connector of Diagnostic POD for ISP connectors 2 with the ISP connector of the programmer with the ISP cable included in d...
Страница 11: ...mming operation IS s insertion lock wn level H selectable from 1 8V Specification PC system insid Microsoft Windows XP Embedded operation s PC Intel Core 2 Duo 2 4 GHz 1024 MB RAM 160 GB HDD PECIFICAT...
Страница 12: ...AMD Ha NV RAM Dallas DSxxx SGS Inmos MKxxx SIMTEK STKxxx XICOR 2xxx ZMD U63x series PLD Altera MAX 3000 A MAX 7000A MAX 7000B MAX 7000S MAX7000AE MAX II PLD Lattice ispGAL22V10x ispLSI1xxx ispLSI1xxxE...
Страница 13: ...SI2xxxE ispLSI2xxxVE ispLSI2xxxVL M4 xx LC4xxxB C V ZC Various PLD also by JAM player JTAG support Altera MAX 3000A MAX 7000A MAX 7000B MAX 7000S MAX 9000 MAX II Xilinx XC9500 XC9500XL XC9500 Notes or...
Страница 14: ...orithms onl r approved or certifie algorithms are used Algorithm updates soft updates a regularly approx ever 4 week free of charge Int et down Dem highly priorit pport and or bugs fixes A load On Mai...
Страница 15: ...JESD 71 VME ispVME file VME2 0 VME3 0 GENERAL operating voltage AC 100 24 power consumption max 300W active dimensions 625x465x115 mm 24 6x18 3x4 5 inch eight programmer w 14 9kg 32 85 lbs temperature...
Страница 16: ...properties of this software and can make a project for mass production Standard device related commands read blank check program verify erase are boosted by some test functions insertion test connecti...
Страница 17: ...oject 1 Connect external display keyboard and mouse to PC connectors on back side of programmer Turn on pr 2 Run the control program double click on icon 3 Find BeeHive8S Site programmer Ctrl F or rig...
Страница 18: ...then click on Connect button 4 Select site Select desired BeeHive8S Site and then click on OK button 5 Select device click on icon and select desired device 6 Load data into buffer from file click on...
Страница 19: ...tions for the device and then click on OK button 8 To customize device use menu Alt S Set desired settings for the device and en click th on OK button tions and Alt S depend on the selected device Not...
Страница 20: ...file connect disconnect programmer sites select desired device master operation blank check verify program erase start stop device operation on connected programmer sites set some advanced options to...
Страница 21: ...ites are successfully found then programmer type and its serial number is show in the table Search result Detected mer can be accepted by pressing touching Accept If no complete programmer was found t...
Страница 22: ...tion tion of devices in programmer sockets and start device operations Insert devices into programmer sockets and press Run touch screen operation means predefined operation for example when predefine...
Страница 23: ...wer The screen is shown during booting up of operating system and starting of standalone control software Pg4uwMC Welcome screen About screen Welcome screen is displayed on Stand Alone build in LCD sc...
Страница 24: ...d and ready to start any operation Present special status of connected Site means the site is connected but it is also not selected checked in dialog Select Sites User selected device or project opera...
Страница 25: ...for example Program Verify Erase C ted device operation for all connected programmer s grammer site But vice operation on all M hich Recent Project name Currently loaded project file name hecksum of d...
Страница 26: ...consequently new drive letter assigned with USB of available drives oject dialog offers two options appear User can sele button Dialog can be closed by Ca p W will appear User can select desired driv...
Страница 27: ...info button ile Make Job Report di level one folder up Note The drive combo box is automatically refreshed each time it is dropped down It is useful for loading project files from USB key which can be...
Страница 28: ...e To switch back to production mode just close Pg4uw control program and run program monitor keyboard and mouse o not use this menu option without these peripherals connected and working omputer It is...
Страница 29: ...is used to reinitialize software configuration and to re find available programmer sites There is no need to use this menu command in normal operation Situations when the command is seful are Stand Al...
Страница 30: ...sites User selected device or project operations will not run on Present unselected sites User can set site selection in dialog Select si accessible by menu lect Enabled sites No project file is loade...
Страница 31: ...S mode is Off operation on next device can be started manually by pressing the YES button near each programmer site socket Each programmer site has its own YES button Status of the active Automatic YE...
Страница 32: ...except d ng running device operation e Options Settings Command displays dialog Settings with list of options user can choose from and set their properties and or settings Log file Log file settings s...
Страница 33: ...information to Log file name allows user to choose additional date information into Log file name When the checkbox is checked the program automatically adds current date string into Log file name thr...
Страница 34: ...of touchpad is recommended if you encounter unexpected reactions alibration with Yes button blank screen with point uired number of points touchpad calibration is complete which will be ayed from touc...
Страница 35: ...operations after which statistics values increment ny selected and performed device operation will increment the counter and one Count down allows checking of the umber of device operations and then...
Страница 36: ...x Protected mode settings due to significance Protected mode is suitable especially for the programming of a large uring next tart of program Pg4uwMC the Protected mode settings from ini file are used...
Страница 37: ...nistrator login is ot necessary M useful when an error occurs in the control program or cturer to updates After selecting is item program will display question Are you sure If user confirms the questi...
Страница 38: ...etter assigned with USB k installation package User can than select this drive and run installation package from the USB key W uring update p D rocess control program of Stand Alone programmer is clos...
Страница 39: ...ddress is the address obtained from DHCP server 127 0 0 1 then no network cable is connected DHCP server is not running when device start or other kinds of error occur refer to troubleshooting chapter...
Страница 40: ...ion program on your computer In mputer field enter IP address from Welcome screen of standalone programmer emote control hrough Microsoft Remo omfortable way to update software control software and sy...
Страница 41: ...stalled In directory Logs are saved log files from operations with devices When OS update files are available they should be saved to Updates directory Your project files should be in Projects directo...
Страница 42: ...ts formatting of disk D and installation of control program mer directory on disk E and creates new one Also mp has been erased and recreated When recovery is close window press A if you accept this a...
Страница 43: ...fill it in following the instructions at the end of the form Use standard ASCII editor Write everything down that you consider being relevant about the programmer software and the target device Send t...
Страница 44: ...file corresponded to your programmer Your new target device ight already be included in this version If yes download the file PG4UWARC exe d install the new version of the control program an Contact...
Страница 45: ...ntenance Warning he ZIF socket of the programmer and the socket converters are considered as onsumables The life cycle of the ZIF socket of the programmer is about echanical cycles The life cycle of Z...
Страница 46: ...ce time and carriag the defective product should be repaired or replaced and judge warranty applies ELNEC has used its best efforts to develop hardware and software that is stable and reliable ELNEC d...