Страница 1: ...SERVICE MANUAL PARTS LIST CE10...

Страница 2: ...Gear 12 Adjusting Upper Shaft Shield Plate Position 13 Adjusting Nedle Thread Tension 14 Adjusting Tension Release Mechanism for Knee Lifter 15 Changing Thread Tension Unit 16 Replacing Threader Plate...

Страница 3: ...1 Face Cover To remove 1 Remove the Cap and Screw A and remove the Face Cover Cap Screw A Face cover To attach 2 Attach the Face Cover and tighten Screw A then attach the Cap Replacing the face cover...

Страница 4: ...Screw A 2 Loosen Screw B and remove Screw C and D 3 Turn the machine to the back and remove Screws C and D then remove the Belt cover Cap Screw A Screw B Screw C Screw D Belt cover To attach 4 Attach...

Страница 5: ...anging External Parts 3 Base Cover Replacing the base cover To remove 1 Remove Screws 4 pieces to remove the base cover Screw Base cover To attach 2 Follow the above procedure in reverse 1 2 1 1 2 1 1...

Страница 6: ...ove the Base Lid 3 Remove Screw B 2 pcs and remove the Bed cover Screw A Base lid Screw B Bed cover To attach 4 Follow the above procedure in reverse Replacing base cap To remove 1 Remove Screws 4 pie...

Страница 7: ...ccessory Screw B To attach 4 Attach the X Y Motor Connectors into the printed circuit board A 5 Insert the X Y Motor Cords between the printed cuircuit board A and Arm without touching the jointing po...

Страница 8: ...D 5 Disconnect the each connector and remove the front cover Note Disconnect the Hooks while removing the Front cover Screw A Arm thread guide Lower Screw B Screw C Screw D Hooks 4 spots To attach 6...

Страница 9: ...2 Loosen Screw A and B 3 Raise the handle and remove Screw C and Cap then remove Screw D Remove the Rear cover Screw A Screw B Carriage Screw C Rear cover Cap Screw D To attach 3 Follow the above proc...

Страница 10: ...oosen Screw move the Needle bar supporter to the right or left until the needle comes to the center of the Needle plate hole 3 Tighten the Screw 4 Attach the face cover Screw Needle bar supporter Need...

Страница 11: ...wheel toward you 4 Raise the needle bar further 3 1 to 3 7 mm from the lowest position 5 Loosen the screws of lower shaft gear turn the Lower shaft gear until the tip of rotary hook meets with the rig...

Страница 12: ...in front of you and tighten Screw 7 Attach the Bobbin holder B Needle plate A presser foot and needle 8 Attach the face cover Needle plate A Bobbin holder B Screw Needle bar Groove Needle 14 Matching...

Страница 13: ...pin and the Tip of rotary hook position to 0 10 to 0 05 mm by moving the rotary hook set plate up or down 4 Tighten the screws A B C firmly 5 Check the rotary hook driver gear and the lower shaft gear...

Страница 14: ...rotary hook 1 Remove the base cover base lid and bed cover See page 3 4 2 Loosen the Hexagonal socket screw 3 A If the backlash is too big or too large turn the lower shaft bushing in the direction o...

Страница 15: ...t shield plate in the direction of B 3 Place the right hand of the Upper shaft shield plate at the center position of the Upper shaft sensor and tighten Setcrew 4 Turn the handwheel toward you to chec...

Страница 16: ...1 Set the Thread tension dial at 3 2 Lower the presser foot 3 Remove the front cover unit and adjust the thread tension A If the thread tension is 59g or more turn the screw in the direction of B B If...

Страница 17: ...spring holder and tighten the Screw A 4 Raise the presser foot lifter turn the thread tension dial from 9 to 0 make sure the clearance between the tension discs should be 1 0 mm 5 Reattach the front c...

Страница 18: ...ee page 6 2 Remove Setscrew A B and remove the thread tension dial To attach 3 Follow the above procedure in reverse Note After the replacement adjust Thread Tension Release Machanism and Adjustment o...

Страница 19: ...sh it up to insert Threader supporter A Pin B Hook Adjusting threader plate position 1 When the hook is slightly touching the nedle eye loosen Screw C and adjust the Threader plate as shown If the hoo...

Страница 20: ...front cover unit See page 6 2 Lower the needle bar and lower the presser foot lifter 3 Insert the 1 2 mm Thickness gauge between the Embroidery Foot P and the needle plate 4 While pressing the Pressu...

Страница 21: ...4 10 6 7 8 9 Touch panel LCD Harness Printed circuit board F Black Bobbin winder sensor Blue Upper shaft sensor White Thread detectionsensor Red Presser foot lifter sensor Red 12 8 9 10 11 13 14 Switc...

Страница 22: ...printed circuit board F LCD Harness Inverter and Touch panel 3 Remove screws 5 pieces and the Printed circuit board A To attach 4 Follow the above procedure in reverse To replace the printed circuit b...

Страница 23: ...rom the Inverter 4 Remove Screws 4 pieces and remove the touch panel To attach 5 While butting the LCD to the ribs A B C spots butt the D and E of the LCD fixing plate bottom to the LCD and tighten sc...

Страница 24: ...below Printed circuit board F To remove 1 Remove the front cover See page 6 2 Pull out the connectors from the printed circuit board A 3 Remove Screws 2 pieces and remove the Printed circuit board F T...

Страница 25: ...Remove the front cover See page 6 2 Loosen Screws 2 pieces 3 Lower the presser foot lifter and adjust the Clearance between the Discs while the discs are closed 4 Tighten Screws 1 2 3 4 Screw A Discs...

Страница 26: ...A 2 pieces temporarily and attach the motor 6 Adjust the motor belt tension and tighten screws A 2 pieces firmly Adjusting motor belt tension 1 Tighten screws B 2 pieces temporarily 2 Adjust the Belt...

Страница 27: ...he Power ON and return the carriage to the home position 4 Remove Screws 3 pieces and remove the carriage plate To attach 5 Attach the carriage plate unit with tightening screws temporarily 6 After th...

Страница 28: ...osition 2 Turn the Power OFF and then remove the base unit 3 Loosen Screw A to adjust dimension Y to moving the Y sensor attachinr plate 4 Loosen screw B to adjust Dimension X 1 to 69 0 mm and Dimensi...

Страница 29: ...and move the Y sensor fixing plate to adjust the needle drop position 7 If the needle position shifts in X direction loosen Screw B through the sheet cover fixing plate hole and adjust the X shield p...

Страница 30: ...the carriage movement 6 Insert a Piece of paper between the thread tension discs as shown so that the needle thread sensor will not work 7 Run the machine and loosen Screws B 2 pieces and move the X m...

Страница 31: ...socket and fixing plate 3 Pull out the Machine socket unit connector 4 Remove screw C and remove the Idler 5 Remove Screws D 2 pieces and Switching power supply to the handwheel side To attach 6 Follo...