Lighting function and additional sounds (channel 3)

The control of the lighting and the additional sounds is made by

channel 3 (orange wire). The activation of the lighting control lead to a

cyclical change of the light condition as shown on the image. 

Status LEDs 

The status LEDs 1 and 2 on the PCB show the current operating status of the 

ElMod 3to

. L1 provides information about the battery status 

(undervoltage) and the connection status to the receiver. L2 informs about the sound output or errors with the identification or reading of the 

microSD card. A permanent lighting of the status LEDs indicates the operating status of the 

ElMod 3to

.

The most important flashing patterns of the central unit's status LED (L1):

on: central unit is ready to operate

LED goes out briefly and goes on again immediately: stick put out of the center

LED blinks quickly: receiver is being scanned, no connection to the receiver or signal invalid

1

LED blinks slowly (shortly on/longer out): communication with sound unit faulty

2

double blinking: battery error of the CPU (undervoltage or short battery disconnection)

3

short blinking every 5 seconds: cut off/shut down due to undervoltage. The battery must be charged or is damaged

single triple blinking: the center unit is in update mode ready to receive a new firmware 

The most important flashing patterns of the sound unit's status LED (L2):

on: sound unit is ready to operate. The LED flickers when sounds are being played

LED blinks rapidly: microSD card faulty, not inserted, no sampleset found or sampleset faulty

LED blinking: no connection to the central unit. Please contact for support.

single triple blinking: the center unit is in update mode ready to receive a new firmware 

1 Please check if your RC and receiver work. Check the correct function with a servo or the ElMod App.
2 If this error doesn't disappear after a restart, please contact your dealer for support.
3 Turn off the electronics for 10 seconds. If the error still exists please ensure that the Configurator is not connected and restart again

© ElMod - 20-01-02

Содержание 3to

Страница 1: ...xternal resistors or other parts are necessary the light connection is short circuit protected The LEDs can t be damaged by false polarity color coded cables with polarity reversal protection are incl...

Страница 2: ...by step It is essential that each step is accomplished correctly and completely Wrong or improper connection may cause malfunction or damage and or destruction of the electronics the installed compon...

Страница 3: ...40 mA The brightness of each light channel can be individually adjusted by the ElMod App Front lighting the LEDs are connected with light channel 1 by one of the provided cable By using two LEDs they...

Страница 4: ...pply connec tion of the receiver If your receiver s connections are not protected against polarity read the manual of the receiver to find out the pin assignment Wrong connected plugs won t damage the...

Страница 5: ...1 LED blinks slowly shortly on longer out communication with sound unit faulty2 double blinking battery error of the CPU undervoltage or short battery disconnection 3 short blinking every 5 seconds cu...

Страница 6: ...ing status to be read out Furthermore firmware updates can be transferred to the ElMod 3to module not yet supported by Android Please note that when installing the software it may be necessary to ensu...

Страница 7: ...operating instructions please contact your dealer s support or another specialist Electrical hazards Supply the device only with low voltage as specified in the technical data Only use current sources...

Страница 8: ...the connection diagram in case of modification and repair attempts of the circuit in case of unauthorized modification of the circuit in case of improper removal of components not provided for in the...

Отзывы: