background image

Chapter 1: Safety Information 

In order to achieve the optimum, safe operation of the PSS power supply, it is imperative 
that you implement the safety procedures included in this user guide. This information is 
provided to protect you and to keep your work area safe when operating the PSS and 
accompanying equipment. Read this chapter carefully before you begin the installation 
process. 

Only qualified personnel may install, adjust, maintain and repair the power supply. A 
“qualified person” has the knowledge and authorization to perform tasks such as 
transporting, assembling, installing, commissioning and operating motors. 

The PSS power supply contains electrostatic-sensitive components that can be damaged if 
handled incorrectly. To prevent any electrostatic damage, avoid contact with highly 
insulating materials, such as plastic film and synthetic fabrics. Place the product on a 
conductive surface and ground yourself in order to discharge any possible static 
electricity build-up. 

To avoid any potential hazards that may cause severe personal injury or damage to the 
product during operation, keep all covers and cabinet doors shut. 

The following safety symbols are used in this manual: 

 

 

Warning:

 

This information is needed to avoid a safety hazard, which might cause 
bodily injury. 

 

 

Caution:

 

This information is necessary for preventing damage to the product or to 
other equipment. 

 

Note: 

This is auxiliary information that ensures the correct operation of the 
equipment. 

1.1 Warnings 

 

 

To avoid electric arcing and hazards to personnel and electrical contacts, 
never connect/disconnect the power supply while the power source is on.

 

 

Power cables can carry a high voltage, even when the motor is not in 
motion. Disconnect the PSS from all voltage sources before it is 
disassembled for servicing. 

 

 

After shutting off the power and removing the power source from your 
equipment, wait at least 5 minutes before touching or disconnecting parts 
of the equipment that are normally loaded with electrical charges (such as 
capacitors or contacts). Measuring the electrical contact points with a 
meter before touching the equipment is recommended. 

Elmo PSS User Guide

 

 

MAN-PSSUG (Ver. 3.01) 

 

1-1 

Содержание PSS 3U

Страница 1: ...PSS User Guide PSS 3U PSS 6U November 2006...

Страница 2: ...No MAN PSSUG Copyright 2003 2006 Elmo Motion Control All rights reserved Product Catalog No PSS F 20 200 R Rated Current H Horizontal Panel Fan Cooling Required Shunt Regulator Power Supply Output Vol...

Страница 3: ...nsional Drawings 2 4 2 5 1 PS1 for PSSF 20 100 and PSSF 20 200 2 5 2 5 2 PS2 for PSS 15 100 and PSS 12 200 2 6 2 5 3 PS3 for PSS 30 200 and PSSF 60 200 2 7 2 5 4 Rack Mount 2 8 Chapter 3 Installation...

Страница 4: ...avoid any potential hazards that may cause severe personal injury or damage to the product during operation keep all covers and cabinet doors shut The following safety symbols are used in this manual...

Страница 5: ...fects in material and workmanship and conform to the specifications stated either within this document or in the product catalog description All Elmo products are warranted for a period of 12 months f...

Страница 6: ...SS in both Horizontal and Rack mount version Table 2 1 covers the Eurocard 3U and Table 2 1 covers the double Eurocard 6U sizes Term Block 32 pin connector Function Comment 0 14a 14c 16a 16c AC 1 supp...

Страница 7: ...er supply is inhibited e g during thermal duty cycle this open collector output goes into low state maximum sink current 10 mA 30 VDC 7 8 J2 Fan supply 24 VDC 0 5 A output for an external brushless fa...

Страница 8: ...ximum DC output 1 VDC 92 92 191 191 191 191 Continuous current A 15 20 12 20 30 60 Peak current A 40 40 40 40 60 100 Panel size see section 2 6 PS2 PS1 PS2 PS1 PS3 PS3 Rack size 3U 21T 3U 12T 3U 21T 3...

Страница 9: ...nal Drawings There are four basic sizes of the PSS PSSF models Panel mount PS1 for 3U 12T size Panel mount PS2 for 3U 21T size Panel mount PS3 for 6U 21T size Rack mount The following sections provide...

Страница 10: ...Elmo PSS User Guide Product Description MAN PSSUG Ver 3 01 2 5 2 5 1 PS1 for PSSF 20 100 and PSSF 20 200 Figure 2 2 PS1 Top View Figure 2 3 PS1 Side View Length Figure 2 4 PS1 Side View Width...

Страница 11: ...ide Product Description MAN PSSUG Ver 3 01 2 6 2 5 2 PS2 for PSS 15 100 and PSS 12 200 16 182 70 Figure 2 5 PS2 Top View 200 Figure 2 6 PS2 Side View Length 4 4 3 3 2 2 1 1 0 0 5 6 109 Figure 2 7 PS2...

Страница 12: ...2 5 3 PS3 for PSS 30 200 and PSSF 60 200 Model PSSF 60 200 includes an integrated fan Figure 2 8 PS3 Top View 200 Figure 2 9 PS3 Side View Length 242 35 Figure 2 10 PS3 Side View Width 16 2 3 4 5 5 1...

Страница 13: ...4 Rack Mount 4 x M3 60 76 1 6 43 84 15 64 7 64 162 54 Figure 2 11 PSS Rack Mount 3U 12T Side View Length 111 76 60 76 1 6 7 64 25 0 2 C A 32 8 128 7 Figure 2 12 PSS Rack Mount 3U 12T Side View Width N...

Страница 14: ...d Current H Horizontal Panel Fan Cooling Required Shunt Regulator Power Supply Output Voltage R Rack Mounting 3 Verify that the PSS model is the one that you ordered and ensure that the voltage meets...

Страница 15: ...to provide better DC bus voltage stability low voltage ripple under high load conditions The recommended AC voltage is 1 2 x VAC min VAC 0 9 x VAC max With a single phase supply a voltage drop due to...

Страница 16: ...IES Figure 3 2 Parallel PSS Wiring All wiring guidelines for supply connections described previously apply to multiple PSS connections 3 3 Startup Procedures 3 3 1 Switching from Single phase to Three...

Страница 17: ...r reforming 1 Connect a 25 VAC supply at the AC input terminals and a 100 W 220 V or 50W 110 VAC light bulb at the power output terminals 2 Run the power supply for an hour and then increase the volta...

Отзывы: